Laserfiche WebLink
Cresson Project – AM-11 Adequacy Review <br />Page 10 <br />May 03, 2016 (Revised May 31, 2016) <br /> <br /> Page 20: The text lists 3 groundwater monitoring wells, GRMW-1A, GRMW-2A, <br />and GRMW-3A, and refers to Figure 2-1. However, none of these monitoring sites <br />are shown on Figure 2-1. Please revise Figure 2-1 to include all monitoring <br />stations discussed in this section. <br />4.4 – Arequa Gulch <br />4.4.1 Current Conditions <br /> Page 22: The text indicates that multiple EMPs may exist for this drainage. On Figure <br />2-1, it appears that there are two EMPs possibly associated with this drainage, EMP- <br />006 and EMP-011. Are these the only EMPs associated with this drainage? <br />4.4.3.1 Monitoring Program <br /> Page 22: The text lists 3 surface water monitoring stations, AG-1.0, AG-1.5, and AG- <br />2.0. However, only two of these sites (AG-1.5 and AG-2.0) are shown on Figure 2-1. <br />Please revise Figure 2-1 to show all monitoring stations discussed in this section. <br />4.4.4.1 Monitoring Program <br /> Page 24: The text lists 7 groundwater monitoring wells, including ESPMW-1, <br />CRMW-3A, CRMW-3B, CRMW-5A, CRMW-5B, CRMW-5C, and CRMW-5D, and <br />refers to Figure 2-1. However, only three of these sites are shown on Figure 2-1 <br />(ESPMW-1, CRMW-3A, and CRMW-3B). Please revise Figure 2-1 to show <br />locations of all monitoring sites discussed in this section. <br />4.5 – Cripple Creek <br />4.5.1 Current Conditions <br /> Page 26: The text indicates that multiple EMPs may exist for this drainage, and refers <br />to Figure 1-1. However, Figure 1-1 does not appear to show any EMPs associated <br />with this drainage. If there are EMPs that exist in this drainage, please show their <br />locations on Figure 1-1. <br />4.5.3.1 Monitoring Program <br /> Page 27: The text lists 4 surface water monitoring locations, including CC-01, CC- <br />02, CC-03, and CC-04, and refers to Figure 2-1. However, Figure 2-1 does not show <br />any of these sites. Please revise Figure 2-1 to include all monitoring sites <br />discussed in this section. Are these stations considered to be compliance sites? <br />4.6 – Grassy Valley <br />4.6.1 Current Conditions <br /> Page 29: The text indicates that multiple EMPs exist for this drainage. Figure 1 -1 <br />shows five EMPs that appear to be associated with this drainage, including EMP-018, <br />EMP-019, EMP-016, EMP-017, and EMP-020. Are these the only EMPs that exist <br />for this drainage? <br />4.6.3.1 Monitoring Program <br /> Page 29: The text lists 3 surface water monitoring stations in this drainage, including <br />GV-01, GV-02, and GV-03, and refers to Figure 2-1. However, only two of these <br />stations are shown on Figure 2-1 (GV-02 and GV-03). Please revise Figure 2-1 to <br />show locations of all monitoring stations discussed in this section.