Laserfiche WebLink
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 <br />Fortune Revenue Silver Mines Inc ACZ Project ID: L24101 <br />ID WORKNUM PARAMETER <br />METHOD�ACZ �NIN i;� <br />QUAL <br />DESCRIPTION <br />L24101-02 WG383316 Lead, total <br />M200.8 ICP -MS <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />WG383256 Chloride <br />SM4500CI-E <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG383204 Cyanide, total <br />M335.4 - Colorimetric w/ <br />M1 <br />Matrix spike recovery was high, the recovery of the <br />distillation <br />associated control sample (LCS or LFB) was acceptable. <br />M335.4 - Colorimetric w/ <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />distillation <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG383201 Cyanide, WAD <br />SM4500-CN LE -Colorimetric w/ <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />distillation <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 O MDL). <br />WG382887 Dissolved Chromium, Hexavalent <br />SM35000r-B <br />H3 <br />Sample was received and analyzed past holding time. <br />SM35000r-B <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG383300 Fluoride <br />SM450OF-C <br />M2 <br />Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />SM450OF-C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG382891 Phosphorus, ortho dissolved <br />M365.1 - Automated Ascorbic <br />QP <br />The sample was filtered at the laboratory more than 15 <br />Acid <br />minutes after sample collection. For Orthophosphate, 40 <br />CFR Part 136.3 requires filtration within 15 minutes of <br />collection. <br />M365.1 - Automated Ascorbic <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />Acid <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M365.1 - Automated Ascorbic <br />ZU <br />Analysis date/time preceeds filter date/time. A portion of <br />Acid <br />sample was filtered and analyzed prior to the creation of a <br />Filter workgroup. <br />WG382936 Residue, Filterable (TDS) @180C <br />SM2540C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG382941 Residue, Non -Filterable (TSS) @105C <br />SM2540D <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG383198 Sulfate <br />D516-02/-07 - Turbidimetric <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />REPAD.15.06.05.01 <br />L24101-1505141447 Page 20 of 29 <br />