Laserfiche WebLink
A CZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334-5493 <br />Fortune Revenue Silver Mines Inc ACZ Project ID: L24101 <br />L24101-01 WG383269 Total Recoverable Digestion <br />WG383316 Lead, total <br />WG383246 Chloride <br />WG383204 Cyanide, total <br />WG383201 Cyanide, WAD <br />WG382887 Dissolved Chromium, Hexavalent <br />WG383300 Fluoride <br />WG382891 Phosphorus, ortho dissolved <br />WG382936 Residue, Filterable (TDS) @180C <br />M200.2 ICP -MS <br />M200.8 ICP -MS <br />SM4500CI-E <br />SM4500CI-E <br />M335.4 - Colorimetric w/ <br />distillation <br />M335.4 - Colorimetric w/ <br />distillation <br />SM4500-CN 1,E-Colorimetricw/ <br />distillation <br />SM3500Cr-B <br />SM3500Cr-B <br />SM3500Cr-B <br />SM450OF-C <br />SM450OF-C <br />M365.1 - Automated Ascorbic <br />Acid <br />M365.1 - Automated Ascorbic <br />Acid <br />M365.1 - Automated Ascorbic <br />Acid <br />SM2540C <br />WG382941 Residue, Non-Filterable(TSS)@105C SM2540D <br />WG383198 Sulfate D516-02/-07 - Turbidimetric <br />REPAD.15.06.05.01 <br />DJ Sample dilution required due to insufficient sample. <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M1 Matrix spike recovery was high, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 O MDL). <br />HE Analysis performed past holding time. Method holding time <br />is less than or equal to 7 days and sample was received <br />with less than half of the holding time remaining (refer to <br />item C5 of ACZ's Terms & Conditions). <br />QD Reported value is the background -corrected concentration, <br />as described by the method. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M2 Matrix spike recovery was low, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />QP The sample was filtered at the laboratory more than 15 <br />minutes after sample collection. For Orthophosphate, 40 <br />CFR Part 136.3 requires filtration within 15 minutes of <br />collection. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />ZU Analysis date/time preceeds filter date/time. A portion of <br />sample was filtered and analyzed prior to the creation of a <br />Filter workgroup. <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M3 The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />L24101-1505141447 Page 19 of 29 <br />