Laserfiche WebLink
• Run logs to TD (1195.6' logger) . Review log; no apparent cement <br />damage to overburden zone. Decision made not to ream well out to 7- <br />7/8 ". <br />October 24 <br />• Plan to land screen at TD. Screen the interval 1160' to 1195'. <br />• Make up the screen assembly from three sections of Johnson Muni - <br />Pak well screen (21D x 4" OD, 4-1/2" nominal, 0.025 slots, SS 304), <br />1@ 5', 1@10', and 1@20'. <br />• Fit with stainless bottom cap (2" NPT threaded) and a 2" NPT to 2- <br />3/8" NUE thread crossover and a stainless steel centralizer set to 6" <br />at the top of the screen section. <br />• Tally a string of solid steel casing /tubing, variable lengths of 2 -3/8" <br />OD, .190 wall, J -55 4.6 ppf, NUE, 10 Rnd thread, galvanized. <br />• Lower screen into well and land. Lift 2" to tension. Hang string from <br />a surface plate. Landing mark (1195) is 6" high. Attribute to slough <br />knocked into hole during installation and to unburied threads at each <br />connection (tallied threads -oft). <br />• Run in the hole with a string of I" tremie pipe and tag the top of the <br />screen at 1160'. <br />• Lift tremie 4', hang, and prepare to pour sand pack. <br />• Sand pack plan: From TD to 5' above top of screen (1155'). Calculate <br />8.7 sacks (50 lbs each, 1012/1020 mix) of Colorado Silica Sand. <br />Poured through the tremie with a water flow. <br />• Pour 9 sks sand, wait 15 min. and tag at 115 1' - Thigh. Uncertain of <br />reason for high tag - water entrained in the sand? <br />• Pull back 5 stands of tremie (210') and pour 1 pail (50 lbs) of Cetco <br />3/8" coated bentonite tablets. <br />NOTE: water began flowing up and out of tubing, but stopped. <br />October 25 <br />• Water flowing out of tubing, - 1 gpm. About 3 gpm flowing up <br />annulus. <br />• Pour 1 pail bentonite pellets to better seal overburden zone. Wait 30 <br />minutes, pour 1 sack of sand to protect seal. <br />• Trip in hole with tremie and tag top of sand at 1147'. <br />NOTE: Calculations for 2 pails of pellets and 1 sack of sand show a <br />fill length of approximately 9' of 6-1/4" hole. This would put top of sand <br />at 1142' if the high tag on 10/24 was correct. If the original calculations <br />for the sand pack were correct and the top of sand was actually approx. <br />1155', the top of the sand - bentonite would be 1146', which is more in <br />line with the tag today. Will go with today's tag of 1147'. <br />