T-W1117'4" <br />Destructs DX -1, DX -3 through DX -8, and DF -14 through DF -39 were cut and tested with passing <br />results. Destructs DF -40 through DF-43 were marked but not yet tested. <br />Approximately 938 lineal feet of anchor trench was excavated and 715 feet was backfilled over <br />the installed liner per project technical specifications. <br />D) Drain Cover Fill (DCF) <br />Ames' crusher operations continued with drain cover fill production <br />Cat 740 trucks hauled drain cover fill to the PSSA. Haul roads for the Cat 740s were maintained <br />at least 4 feet above the secondary geomembrane and HVSCS piping. <br />Ames continued placing and finish - grading DCF on approved primary liner with Cat GPS dozers <br />on panels P80 to P93; P100 to P112; P115 to P118; P126 to P140; and P154 to P156. A track <br />hoe placed DCF material on the 28" HVSCS piping that was placed on the floor of the PSSA. <br />See the attached DCF map for all placement <br />E) High Volume Solution Collection System Piping ( HVSCS): <br />Fusion welding continued on the HVSCS 28 -inch HDPE piping in the PSSA floor. <br />28" HDPE piping was inserted over the 28" slip joint on the central primary 28" HVSCS pipe and <br />approximately 400' was placed on primary geomembrane and as -built surveyed. <br />II) Storm Water Management <br />Best Management Practices (BMPs) are being performed. <br />CQA ACTIVITIES: <br />1) Field Activities: Field activities and observation during this reporting period included: Slope grading <br />and fill placement; nuclear density and moisture testing; HVSCS pipe fusion and layout; Phase 1 <br />surface acceptance; DCF, SLF, and SF sampling. <br />II) Laboratory Activities: Permeability, Atterberg limits, moisture, and sieve analysis laboratory testing <br />continued. <br />The following samples were collected and returned to AMEC's laboratory for analysis: <br />Drain Cover Fill sample DCF 116 (Control sample) <br />➢ Structural Fill sample SF 102 -R through SF 104 -R (Record sample) <br />➢ Soil Liner Fill samples 1SLF -2R and 1SLF -3R (Record samples) <br />Soil Liner Fill samples SLF -160C (Control sample from the Cameron site) <br />2014- 11 -01 -MLE2 WEEKLY FINAL Page 3 of 7 <br />