My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-09-29_PERMIT FILE - M2012032
DRMS
>
Day Forward
>
Permit File
>
Minerals
>
M2012032
>
2014-09-29_PERMIT FILE - M2012032
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:48:10 PM
Creation date
10/1/2014 3:16:44 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2012032
IBM Index Class Name
PERMIT FILE
Doc Date
9/29/2014
Doc Name
MSDS Pages for material containment plan
From
Star Mine Operations LLC
To
DRMS
Email Name
RCO
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
31
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MATERIAL SAFETY DATA SHEET REVISION No. 03 <br />FLOTTEC PAX COLLECTOR SUPERSEDES: 02/19/2007 <br />NOVEMBER 1, 2009 H-a7zF <br />maxtm/rinR the valos Motatlon CRem /cu /s Tschnotaary <br />14. FIRST AID MEASURES <br />INGESTION: If swallowed, call a physician immediately. Only induce vomiting at the instruction of a physician. Never give <br />anything by mouth to an unconscious person. <br />SKIN CONTACT: Remove contaminated clothing and shoes without delay. Wash immediately with plenty of water. Do not reuse <br />contaminated clothing without laundering. Get medical attention if pain or irritation persists after washing or if <br />signs and symptoms of overexposure appear. <br />EYE CONTACT: Rinse immediately with plenty of water for at least 15 minutes. Obtain medical attention immediately. <br />INHALATION: Remove to fresh air. If breathing is difficult, give oxygen. Obtain medical advice if there are persistent symptoms. <br />EXTINGUISHING MEDIA AND FIRE FIGHTING INSTRUCTIONS <br />Extinguishing <br />Use carbon dioxide, dry chemical or large quantities of water. <br />Media: <br />Protective <br />Firefighters, and others exposed, wear self- contained breathing apparatus. Wear full firefighting protective <br />Equipment' <br />clothing. See MSDS Section 8 (Exposure Controls /Personal Protection). <br />Special <br />Solid xanthates are stable when kept cool and dry. Exposure to heat and moisture can cause decomposition to <br />Hazards' <br />' <br />flammable and explosive vapor of carbon disulfide. Since xanthates decompose in solution, even at room <br />solutions, (2) draining mobile tanks, (3) cleaning mobile tanks, and (4) performing maintenance work on storage <br />temperature, fire and explosion hazards can develop with aging. <br />tanks and pipelines leading to and from tanks. Use non - sparking tools and do not smoke when opening drums of <br />6. ACCIDENTAL RELEASE MEASURES <br />PERSONAL <br />Where exposure level is not known, wear approved, positive pressure, self - contained respirator. Where exposure <br />PRECAUTIONS: <br />level is known, wear approved respirator suitable for level of exposure. Refer to Section 8 (Exposure <br />Controls /Personal Protection) for appropriate personal protective equipment. <br />METHODS FOR <br />Sweep up into containers for disposal. Flush spill area with water. <br />CLEAN UP: <br />ENVIRONMENTAL <br />Dispose of in accordance with EPA rules and regulations. <br />PRECAUTIONS: <br />HANDLING <br />Precautionary <br />Avoid excessive heat or moisture. Avoid contact with eyes, skin and clothing. Avoid breathing dust. Keep <br />Measures : <br />container closed. Wash thoroughly after handling. Use non - sparking tools and do not smoke when opening drum. <br />Use with adequate ventilation. Contains finely divided material. Dust suspended in air may ignite with static <br />discharge, sparks or flame. Equipment, including venting systems, should be grounded. Provide adequate <br />ventilation in areas of use to remove dust. Wash contaminated clothing before reuse. <br />Special Handling <br />Minimize dust. Special precautions against fire and explosion must be observed in (1) pumping xanthate <br />Statements : <br />solutions, (2) draining mobile tanks, (3) cleaning mobile tanks, and (4) performing maintenance work on storage <br />tanks and pipelines leading to and from tanks. Use non - sparking tools and do not smoke when opening drums of <br />xanthate. DUST EXPLOSION HAZARD CLASS - 2 Handling of material should be in accordance with standards for <br />venting of deflagration (e.g. NFPA -68). If handled with flammable or combustible materials the explosion hazard <br />may increase <br />STORAGE Heating or overexposure to moisture of solid xanthates or heating or aging of xanthate solutions causes some <br />decomposition to poisonous and flammable carbon disulfide. Storage tanks should have certain design features <br />for maximum safety, and the vapor space should be free of sources of ignition. <br />Storage Store at <32.2 - 10 °C 90 - 50 °F <br />Temperature: Reason: Safety <br />Page 2 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.