Laserfiche WebLink
LABORATORY COMPACTION CHARACTERISTICS OF SOIL REPORT Irerracon <br /> Report Number: 69121002.0009 <br /> Service Date: 02/13/12 #4 A CR 3499 <br /> Report Date: 02/17/12 Flora Vista,NM 87415 <br /> 505-334-2900 <br /> Client Project <br /> Wildcat Mining Corporation Wildcat Mining/Laboratory Testing Services <br /> Attn: David McLay Laboratory <br /> 5555 DTC Parkway Flora Vista,NM 87415 <br /> Suite A-4000 <br /> Greenwood Village,CO 80111 Project Number 69121002 <br /> Material Information Sample Information <br /> Source of Material: RWTP-01 Sample Date: 01/13/12 Sample Time: 1350 <br /> Proposed Use: Sampled By: Client <br /> Sample Location: RWTP-01 @ 3-4' <br /> Sample Description: <br /> Laboratory Test Data Result Specifications <br /> Test Procedure: ASTM D 1557 Liquid Limit: <br /> Test Method: Method B Plastic Limit: <br /> Sample Preparation: Wet Plasticity Index: <br /> Rammer Type: Mechanical In-Place Moisture(%): 5.5 <br /> Passing 3/4"(%): 89.0 <br /> Passing 3/8 "(%): 75.0 <br /> USCS: <br /> Oversized Particles(%): 25.0 Zero Air Voids Curve for Assumed Specific <br /> Moisture(%): 1.0 Gravity 2.70 <br /> Sieve for Oversize Fraction: 3/8 144 <br /> M 143 <br /> V <br /> a 142 <br /> 1a1 <br /> Assumed Bulk Specific Gravity V <br /> t <br /> of Oversized Particles: 2.65 01 141 <br /> N 139 <br /> 3 138 <br /> Corrected for Oversized Particles(ASTM D4718) 137 <br /> Maximum Dry Unit Weight(pcf): 142.3 136 <br /> 35 <br /> Optimum Water Content(%): 5.4 <br /> 134 Uncorrected Values 1 2 3 a s s a s 10 <br /> Maximum Dry Unit Weight(pcf): 136.2 Water Content(%) <br /> Optimum Water Content(%): 6.9 <br /> Comments: Performed testing on samples provided by Mr. Dave McLay with Wildcat Mining Corporation to our Flora Vista,New <br /> Mexico laboratory. <br /> Services: Modified Proctor Test(ASTM 1557)and Moisture Content(ASTM D2216) <br /> Terracon Rep.: Client <br /> Reported To: <br /> Contractor: <br /> Report Distribution: <br /> (1)Wildcat Mining Corporation (1)Terracon Consultants,Inc. <br /> —�7 <br /> Reviewed By: <br /> Zachary St Jean <br /> Department Manager II-Professional <br /> Test Methods: ASTM D 1557 <br /> The tests were performed in general accordance with applicable ASTM,AASHTO,or DOT test methods. This report is exclusively for the use of <br /> the client indicated above and shall not be reproduced except in full without the written consent of our company. Test results transmitted herein <br /> are only applicable to the actual samples tested at the location(s)referenced and are not necessarily indicative of the properties of other apparently <br /> similar or identical materials. <br /> CROOW 8-27-11.Roy 6 Page I of I <br />