Laserfiche WebLink
ACZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Golder Associates ACZ Project ID: L16930 <br />L16930 -06 WG359798 <br />Copper, dissolved <br />M200.7 ICP <br />01 <br />Sample required dilution due to matrix. <br />Zinc, dissolved <br />M200.7 ICP <br />D1 <br />Sample required dilution due to matrix. <br />WG359985 <br />Chloride <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG359986 <br />Fluoride <br />SM450OF -C <br />M1 <br />Matrix spike recovery was high, the recovery of the <br />associated control sample (LCS or LFB) was acceptable. <br />SM450OF -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG359985 <br />Sulfate <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non- target analyte exceeded <br />calibration range. <br />L16930 -07 WG359798 <br />Copper, dissolved <br />M200.7 ICP <br />D1 <br />Sample required dilution due to matrix. <br />Zinc, dissolved <br />M200.7 ICP <br />D1 <br />Sample required dilution due to matrix. <br />WG359985 <br />Chloride <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL). <br />WG359883 <br />Fluoride <br />SM450OF -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG359985 <br />Sulfate <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non - target analyte exceeded <br />calibration range. <br />L16930 -08 WG359741 <br />Barium, dissolved <br />M200.7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />WG359985 <br />Chloride <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG359883 <br />Fluoride <br />SM450OF -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />L16930 -09 WG359741 <br />Barium, dissolved <br />M200.7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level. The recovery of the associated control sample (LCS <br />or LFB) was acceptable. <br />Sodium, dissolved <br />M200.7 ICP <br />BB <br />Target analyte detected in calibration blank at or above <br />acceptance limit. Sample value was > 1 OX the <br />concentration in the calibration blank. <br />WG359985 <br />Chloride <br />M300.0 - Ion Chromatography <br />DC <br />Sample required dilution. Non - target analyte exceeded <br />calibration range. <br />M300.0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG359883 <br />Fluoride <br />SM450OF -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 O MDL). <br />REPAD.15.06.05.01 <br />L16930- 1403041518 Page 19 of 23 <br />