My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2009-07-07_REPORT - M1980244 (6)
DRMS
>
Day Forward
>
Report
>
Minerals
>
M1980244
>
2009-07-07_REPORT - M1980244 (6)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 3:48:33 PM
Creation date
2/26/2014 9:30:44 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Report
Doc Date
7/7/2009
Doc Name
QA July 7,2009: Load out Bin Relpcation Doc 1 of 7
From
CC&V
To
DRMS
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
232
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cripple Creek & Victor Gold Mining Company <br />Cresson Project <br />Quality Assurance Monitoring and Test Results <br />Load Out Bin Relocation <br />July 7, 2009 <br />ameO <br />The laboratory test results are summarized in Tables 5, 6 and 7 and presented in Appendix H. <br />4.1.1 Grain Size Distribution <br />AMEC completed the grain size distribution (gradation) of samples of SF, SLF, and DCF. The <br />results of gradation analyses are presented in Appendix H -1 and summarized in Tables 5 <br />through 7. <br />■ AMEC performed 2 CQA gradations of SF. The testing frequency (approximately one <br />test per 1,000 cubic yards) exceeded the minimum specified testing frequency of one <br />test per 50,000 cubic yards. The CQA gradations performed on SF met project <br />specifications. The SF CQA gradation results are presented in Appendix H -1 and <br />summarized in Table 5. <br />■ AMEC performed 2 CQA gradations of SLF. The testing frequency (approximately one <br />test per 623 cubic yards) exceeded the minimum specified testing frequency of one test <br />per 5,000 cubic yards. The CQA gradations performed of SLF met project <br />specifications. The SLF CQA gradation results are presented in Appendix H -1 and <br />summarized in Table 6. <br />■ AMEC performed 3 CQA gradations of DCF. The testing frequency (approximately one <br />test per 1,075 cubic yards) exceeded the minimum specified testing frequency of one <br />test per 20,000 cubic yards. The DCF CQA gradations met project specifications, and <br />the results are presented in Appendix H -1 and summarized in Table 7. <br />4.1.2 Moisture Content <br />AMEC measured oven moisture contents of SF, SLF, and DCF as part of the CQA program. <br />Moisture content data are presented in Appendix H -1. <br />4.1.3 Atterberg Limits <br />AMEC performed Atterberg limit testing of all fill materials. All fill materials, with the exception of <br />SF and SLF were non - plastic. The SLF, SF, and DCF samples tested met project specifications <br />for Atterberg Limits. <br />The SLF Atterberg limits testing frequency (approximately one test per 623 cubic yards) <br />exceeded the minimum specified testing frequency of one test per 5,000 cubic yards. The <br />plasticity index of the CQA SLF samples were both 29, meeting the project specification of <br />plasticity index greater than or equal to 10. Atterberg limit test results for SLF are presented in <br />Appendix H -1 and summarized in Table 6. <br />S: \PROJECTS \1125E CCV CQA \H3 - CONSTRUCTION \LOB CERT REPORT\REPORT BODY\LOB CERT REPORT 2009.07.01.DOC 11 <br />
The URL can be used to link to this page
Your browser does not support the video tag.