My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2010-08-10_REPORT - m1980244
DRMS
>
Day Forward
>
Report
>
Minerals
>
M1980244
>
2010-08-10_REPORT - m1980244
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 4:17:42 PM
Creation date
2/26/2014 9:22:36 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
m1980244
IBM Index Class Name
REPORT
Doc Date
8/10/2010
Doc Name
QA REPORT Phase 4B/C Triangle Liner Certification Aug 10, 2010
From
CC&V
To
DRMS
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
255
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Cripple Creek & Victor Gold Mining Company <br />Cresson Project <br />Quality Assurance Monitoring and Test Results <br />Phase 4B /C Triangle Liner Certification <br />August 10, 2010 <br />areas that were observed to be rough or inadequate, as discussed in Section 6.1.2. AMEC and <br />Lonestar approved the final surface of the SLF prior to geomembrane deployment. <br />4.2.3.2 Moisture - Density Test Results <br />AMEC performed a total of four (4) in -place moisture - density tests of SLF. AMEC compared <br />results of the field moisture content and density tests to the Proctor dry density and optimum <br />moisture content values of material with similar gradation and plasticity characteristics. Proctor <br />dry density and optimum moisture content values for samples with greater than ten percent plus <br />three - quarter -inch material were corrected according to ASTM D4718 to facilitate direct <br />comparison to nuclear density values. The moisture - density testing frequency of approximately <br />one test per 75 cubic yards exceeded the minimum specified testing frequency of one test per <br />500 cubic yards. Nuclear density tests performed for the Phase 4B /4C Triangle certification <br />SLF are summarized in Table 6. Holes made in the SLF during testing were filled by tamping <br />fine SLF or bentonite material into the holes. <br />4.2.3.3 Depth Verification <br />AMEC drilled a total of two (2) holes in the compacted SLF to verify that the minimum 12 -inch <br />compacted depth had been achieved. AMEC monitored the SLF depth verification tests and <br />documented results. Depth verification holes were filled with bentonite chips and water. Both of <br />the holes drilled into the SLF had compacted depths of 12 inches. The testing frequency <br />exceeded the minimum specified testing frequency of two measurements per acre. The SLF <br />depth verification results are presented in Table 7. <br />4.2.4 Drain Cover Fill <br />AMEC provided visual monitoring of DCF placement. One AMEC monitor and at least two <br />Ames laborers were present monitoring each dozer, unless two dozers were within <br />approximately 50 feet of each other during DCF placement. AMEC verified that wrinkles in the <br />geomembrane did not fold over, that PVC grade markers were placed at grade breaks, and that <br />unsuitable material was not present in the fill. AMEC continuously inspected geomembrane <br />during DCF placement, and marked areas for repair, if required. If needed, any repairs were <br />documented and AMEC verified the repairs were completed. After final grading, AMEC <br />monitored removal of PVC grade markers. <br />4.2.5 Temperature Monitoring <br />AMEC monitored ambient air temperatures using a digital thermometer. Temperatures were <br />monitored throughout the day. The lowest and highest daily temperatures are summarized in <br />Table 2. <br />S \PROJECTS \1125E CCV CQA \H2 - DESIGN \TRIANGLE \FINAL \TRIANGLE CERTIFICATION REPORT FINAL REV1 DOC 12 <br />
The URL can be used to link to this page
Your browser does not support the video tag.