My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2001-10-25_REPORT - M1980244
DRMS
>
Day Forward
>
Report
>
Minerals
>
M1980244
>
2001-10-25_REPORT - M1980244
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/26/2021 1:56:35 PM
Creation date
2/25/2014 5:46:19 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
REPORT
Doc Date
10/25/2001
Doc Name
Final Report QA Oct 2001for "External Pond" Doc 1 of 10
From
CC&V
To
DRMS
Media Type
D
Archive
No
Tags
DRMS Re-OCR
Description:
Signifies Re-OCR Process Performed
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
228
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
October 2001 -14- 003-2182.004 <br /> ► Rock corrected density values (ASTM D4718); <br /> ► Grain size distribution (ASTM D 1140 for material finer than the No. 200 <br /> sieve, and ASTM C 117 and C 136 for coarse material); <br /> ► Moisture content(ASTM D2216); <br /> ► Atterberg limits (ASTM D4318); <br /> ► Standard Proctor compaction(ASTM D698); <br /> ► Permeability(ASTM D5084, Method D); <br /> ► In-place density testing (ASTM D2922); and <br /> ► Bulk specific gravity(ASTM C127). <br /> Golder conducted appropriate tests as required by the specifications for Subgrade Structural <br /> Fill, Structural Fill, Leak Detection Fill, Soil Liner Fill,Pipe Bedding Fill, and Base Course. <br /> The laboratory test results are summarized in Tables 4 through 8 and presented in Appendix G. <br /> 4.1.1 Grain Size Distribution <br /> Golder analyzed the grain size distribution (gradation) of samples of Subgrade Structural Fill, <br /> Structural Fill, Leak Detection Fill, Soil Liner Fill, Pipe Bedding Fill, and Base Course. The <br /> results of gradation analyses are presented in Appendix G-1 and summarized in Tables 4 <br /> through 8. <br /> Golder performed four CQA gradations of Structural Fill. The testing frequency <br /> (approximately one test per 14,400 cubic yards) exceeded the minimum specified testing <br /> frequency of one test per 50,000 cubic yards. The CQA gradations performed on Structural Fill <br /> met project specifications. The Structural Fill CQA gradation results are presented in Appendix <br /> G-1 and summarized in Table 4. <br /> I\00\2182\EXTERNAL POND RPTTINAL.DOC Golder Associates <br />
The URL can be used to link to this page
Your browser does not support the video tag.