My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2014-02-07_REPORT - M1980244 (8)
DRMS
>
Day Forward
>
Report
>
Minerals
>
M1980244
>
2014-02-07_REPORT - M1980244 (8)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
9/4/2020 4:33:08 AM
Creation date
2/11/2014 12:55:47 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1980244
IBM Index Class Name
Report
Doc Date
2/7/2014
Doc Name
Final Report QA Monitoring and testing volume 2 of 2 document 1 of 3Mill Site Earth works
From
CC&V
To
DRMS
Email Name
TC1
Media Type
D
Archive
No
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
367
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ameO <br /> 2. CONTRACTOR shall place and compact the Bedding Fill in loose lifts such that the <br /> compacted lift thickness is a minimum of 12-inches. CONTRACTOR shall condition the <br /> Bedding Fill to allow a surface that does not cause rutting or other deleterious effects. The <br /> moisture content and density shall be uniform throughout the lift. If a lift of compacted <br /> Bedding Fill dries out during placement operations, CONTRACTOR shall scarify, <br /> moisture condition the dry soil and recompact the lift. If a lift of compacted Bedding Fill <br /> becomes overly wet due to precipitation or over watering,CONTRACTOR shall allow the <br /> wet soil to dry to the specified moisture content range before recompaction of fill and <br /> placement of geosynthetic materials. <br /> 3. CONTRACTOR shall assist CQA Monitor in obtaining soil samples for CQA testing. <br /> Bedding Fill sampling shall be scheduled by CQA Monitor with CONTRACTOR to <br /> facilitate CQA field testing. <br /> 4. CONTRACTOR shall trim the surface of the Bedding Fill to the design grades shown on <br /> the DRAWINGS. <br /> 5. CONTRACTOR shall roll the surface of the Bedding Fill with a smooth drum roller to <br /> remove ridges and surface irregularities greater than 0.5 inches in height. CERTIFYING <br /> ENGINEER shall determine if surface preparation is sufficient to place geomembrane. On <br /> areas with slopes steeper than 3H:1 V, CONTRACTOR shall adopt methods as necessary <br /> to obtain the same final surface preparations that would be obtained by the passage of a <br /> smooth-drum roller on flat or level ground. Pushing of compaction equipment by tracked <br /> equipment shall not be performed. Wheel ruts on the surface of the Bedding Fill from <br /> grading equipment shall be repaired by CONTRACTOR prior to placement of the <br /> geomembrane by rolling the surface as approved by CQA Monitor. CONTRACTOR shall <br /> take whatever steps necessary to prepare BeddingFill surface to the satisfaction of <br /> MANAGER and CERTIFYING ENGINEER,at no additional cost to CC&V. <br /> 6. CONTRACTOR shall maintain the Bedding Fill surface in a condition suitable for <br /> geomembrane installation as specified in these SPECIFICATIONS and in the CQA Plan <br /> until the surface is covered. CONTRACTOR shall repair all weather related damage to <br /> Bedding Fill surfaces or other portions of the work that have or have not been covered by <br /> geomembrane,at no additional cost to CC&V. <br /> If any moisture is allowed to collect under the geomembrane prior to or after final seaming <br /> and softens the Bedding Fill, the geomembrane shall be removed and CONTRACTOR <br /> shall recondition and recompact the Bedding Fill to meet all placement and trimming <br /> SPECIFICATIONS,at no additional cost to CC&V. <br /> 7. CONTRACTOR shall remove all hubs and survey stakes in the Bedding Fill and backfill <br /> all holes with MANAGER and CERTIFYING ENGINEER approved material. <br /> 8. CONTRACTOR shall verify the final thickness of Bedding Fill to determine compliance <br /> with this SPECIFICATION. CONTRACTOR shall record as part of the as-built <br /> documentation the location, elevation, and thickness of each Bedding Fill verification test. <br /> CQA Monitor will witness all verification measurements. Areas with deficiencies shall be <br /> reworked by CONTRACTOR, until acceptable measurements are obtained at no <br /> additional cost to CC&V. If tests indicate the Work does not meet the requirements of the <br /> SPECIFICATIONS, MANAGER and CERTIFYING ENGINEER will establish the <br /> extent of the nonconforming area. The nonconforming area shall be reworked by <br /> CONTRACTOR until acceptable test results are obtained at no additional cost to CC&V <br /> Section 02200 Page 15 of 16 May 9,2012 <br /> Earthworks Revision 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.