Laserfiche WebLink
ameO <br /> TABLE2 <br /> SOIL CONSTRUCTION TESTING FREQUENCY <br /> VOLUME PER TEST' <br /> Test and Bedding Fill Soil Liner Drain Cover <br /> ASTM and Pipe Bedding Fill Fill Fill <br /> Designation c c c <br /> Compaction -- 4,000 -- <br /> ASTM D698 <br /> Particle Size`' 10,000 4,000 20,000 <br /> ASTM C117,C136,D1140 <br /> Atterberg Limit 10,000 4,000 20,000 <br /> (ASTM D4318) <br /> Moisture Content3 10,000 500 20,000 <br /> (ASTM D2216) <br /> Permeability4 <br /> 4,000 <br /> ASTM D5084/2434 <br /> Nuclear Density -- 500 -- <br /> 1. Tests shall be performed at the specified frequency or one per material type,whichever is greater. <br /> 2. Use the USCS for description and identification(ASTM D2488). <br /> 3. In-place Moisture Content. <br /> 4. Permeability testing will be performed during the processing of the Soil Liner Fill material, certifying the <br /> processed stockpile. <br /> *** END OF SECTION*** <br /> Section 01400 1 Page 10 of 10 May 9,2012 <br /> Earthworks CQA Plan Revision 1 <br />