My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
WSP05040
CWCB
>
Water Supply Protection
>
Backfile
>
5001-6000
>
WSP05040
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/26/2010 2:16:41 PM
Creation date
10/12/2006 12:48:15 AM
Metadata
Fields
Template:
Water Supply Protection
File Number
8510.100.60
Description
Rio Grande Compact Commission
Basin
Rio Grande
Water Division
3
Date
1/1/1979
Title
Report of the Rio Grande Compact Commission 1979
Water Supply Pro - Doc Type
Report/Study
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
58
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />!~'.(,:.,:'::: ;:~,'-",::'{," ".,S~"","~",~;,:"~_;,:-~,,,;~,.,t..1t\.,:-':;.;-,..,,~.,,,-.. -~''-:,"'-''."'~,_. '.'.,,'''' ".' .,-.^",>~ ,-".,," <br /> <br />C'J <br />v-4 <br />'" <br />(- .. 32 <br />(j <br />C:.-.~ <br /> <br /> <br />RIO GRANDE COMPACT COMMISSION REPORT <br /> <br /><~~..u..",ij-, <br /> <br />ACCURACY OF RECORDS <br /> <br /> <br />The Rules and Regulations of the Commission state that the equip- <br />ment, method. and frequency of measurement at each gaging station shall <br />be sufficient to obtain records at least equal in accuracy to those <br />classified as "good" by the U.S. Geological Survey. Within the <br />physical limitations of stream gaging. the agencies obtaining the <br />records. at Compact gaging stations have compiled with these <br />regulations. <br /> <br />The accuracy of discharge data depends primarily on (1) the <br />stability of the stage-discharge relation, or if the control is un- <br />stable, the frequency of discharge measurements, and (2) the accuracy <br />of observations of stage, measurements of discharge, and interpre- <br />tation of records. <br /> <br />The station description states the degree of accuracy of the <br />daily records. "Excellent" means that about 95 percent of the daily <br />discharges are considered to be within 5 percent of true value; <br />"good" within 10 percent; and "fair" within 15 percent. "Poor" <br />means that daily discharges have less than "fair" accuracy. <br /> <br />The phrase "within 5% of true value" used to qualify "excellent" <br />records establishes the extremes of the probable errors for 95% of <br />the days in a given period of time. The word "within" defines the <br />range of errors with individual daily values falling between 95% <br />and 105% of true value. The probable error in a monthly or annual <br />mean discharge depends more on the distribution of the daily errors <br />between these two limits than it does on the limits themselves. <br />For this reason monthly and annual records are much more accurate <br />than most daily records. <br /> <br /> <br />t:~;~ <br />~f~j;< <br />[.1t~~~,~~, <br />
The URL can be used to link to this page
Your browser does not support the video tag.