Laserfiche WebLink
<br />'--.,/ <br /> <br />.' <br /> <br />002393 <br /> <br />Definitions of OM&R from FAC and SOP <br /> <br />ELECTRICAL, MECHANICAL, AND STRUCTURAL <br /> <br />Miscellaneous O&M <br /> <br />Multiple Gate Openings <br />High-pressure Slide Gate Minimum Openings <br />Drop-inlet Outlet Works Operation <br />Ventilation Systems Operation <br />Rock Removal from Chutes and Basins <br />Isolation and Bypass Valves <br />Gates and Valves - Exercising and Testing <br /> <br />Dam Maintenance <br /> <br />Clearing trees and shrubbery from the embankment dam slopes <br />Cleaning drains <br />Exercising gates and valves <br />Painting concrete and metalwork <br /> <br />-I <br /> <br />,... - <br />'~ <br />I <br /> <br />Dam Inspection <br /> <br />Embankment Dam Inspection <br />o Cracks <br />o Sinkholes <br />o Slides <br />o Impairments of slope protection <br />o Sloughs <br />o Subsidence <br />o Undesirable vegetation <br />o New seeps <br />o Changes in existing seeps or wet area <br />o Animal burrows <br />o Boils at the downstream toe area <br />o Beaching conditions or damage to riprap slope protection <br />Concrete/Masonry Dam Inspection <br />o Cracks <br />o Surface defects <br />o Leakage, and Seepage <br />o Concrete/Masomy deterioration <br />o Displacement (misalignment or differential movement) <br />o Drainage system (e.g" gallery drainage gutters, formed drains (face drains <br />and joint drains), foundation drains (drill holes)) <br />Appurtenant Structures Inspection <br /> <br />'~ <br />-! <br /> <br />~l <br />I <br /> <br />t" ".- <br />