Laserfiche WebLink
<br />1";0 <br /> <br />~/7 <br />~~'.,! <br /> <br />C',! <br />I....,~J <br />'-' <br /> <br />2. EARTHQUAKE <br /> <br />LATITUDE: 37021'07" <br /> <br />LONGITUDE: 106032'38" <br /> <br />ZONE: Platoro dam is located in an area subject to earthquakes <br /> <br />of zone 2 damaging intensity. <br /> <br />SEISMIC EVALUATION: An evaluation has not been done at this time. <br /> <br />If you have felt an earthquake or one has been reported to have occurred <br /> <br />in the area with a Richter magnitude (M) of 4.0M or greater within a <br /> <br />10-mile radius, 5.5M or greater within a 60-mile radius, or 6.5M or <br /> <br />greater within a 100-mile radius from the site, follow the procedures <br /> <br />below: <br /> <br />a. Immediately conduct a general overall visual inspection of <br /> <br />the dam. <br /> <br />b. IF THE DAM IS DAMAGED TO THE EXTENT THAT THERE IS INCREASED <br /> <br />FLOW PASSING DOWNSTREAM, UlMEDIATELY IMPLEMENT "FAILURE OR IMPENDING <br /> <br />FAILURE" PROCEDURES UNDER NUMBER 1. <br /> <br />c. If visible damage has occurred but has not been serious <br /> <br />enough to cause failure of the dam, make the following observations and <br /> <br />" <br /> <br />contacts immediately: <br /> <br />A-9 <br /> <br />- <br />