My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PROJ00553
CWCB
>
Loan Projects
>
Backfile
>
1-1000
>
PROJ00553
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2009 11:43:28 AM
Creation date
10/6/2006 12:01:22 AM
Metadata
Fields
Template:
Loan Projects
Contract/PO #
FS0022X
Contractor Name
West Anvil Water & Power Company
Contract Type
Loan
Water District
0
County
Garfield
Loan Projects - Doc Type
Feasibility Study
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
368
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />. <br /> <br />the reservoir-filling criteria. As the inflows to the reservoir <br />exceed the discharge capacity of the hydroturbines, the bypass outlet <br />will supplement passing the spring flood runoff through the gated <br />spi 11 way . <br /> <br />The discharge capacity of the low-level bypass outlet is illustrated <br />in Figure III-2. With the valve 100% open, the outlet's discharge <br />capacity will range from 1,352 cfs at a reservoir pool elevation of <br />5,220 ft to 1,913 cfs at a reservoir elevation of 5,250 ft. The <br />bypass outlet and the power outlets combined will discharge 8,513 cfs <br />at a normal pool elevation of 5,250 ft. Inflows to the reservoir in <br />excess of 8,513 cfs will be discharged by the gated overflow spill- <br />way. <br /> <br />. <br /> <br />D. GATED SPILLWAY <br />In addition to the power and bypass outlets, there will be a gated <br />spi 11 way to release high flows dur i ng the occurrence of a 500-year <br />flood and spring floods. These flows cannot be contained in the <br />limited surcharge storage available in the reservoir. Therefore, <br />spi 11 way flows will result during the spring flood period in all <br />years of flow except dry years. The spillway also provides head <br />control for power generation, and supplements or replaces the bypass <br />outlet operation when the reservoir level is within the surcharge <br />storage space. <br /> <br />The spi 11 way gates wi 11 operate so that they will open automat ica lly <br />at successively increasing reservoir levels above a normal reservoir <br />pool elevation of 5,250 ft. Figure 111-3 shows the spillway <br />discharge at various reservoir levels and gate openings. Each radial <br />gate will be equipped with a power hoist and will be partially <br />counterbalanced for manual control. An alternate power source is <br />provided at the powerhouse to reduce the risk of the gates being <br /> <br />. <br /> <br />3686-a/7 <br /> <br />II 1-4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.