<br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />These MM intensities may be correlated to average peak velocity and acceleration as given in <br />Table 6.7. <br /> <br /> TABLE 6.7 <br />MODIFIED MEReALLI SeALE eORRELATIONS <br />Modified Mercalli Average Peak Average Peak <br />Scale Intensity Velocity Acceleration <br /> (cmls) (g) <br />V 2-5 0.03 - 0.05 <br />VI 5 - 8 0.05 - 0.07 <br /> <br />The U.S. Army Corps of Engineers (USAeE) has developed general guidelines for the seismic <br />design and evaluation of all USACE civil works projects. The USAeE (1983) has developed <br />a seismic zone map Cor the United States. The project site lies in Seismic Zone 1, for which <br />the recommended seismic design coefficient is 0.05 g. <br /> <br />Algermissen et. aI (1990) have developed maps showing peak seismically induced horizontal <br />ground velocity and acceleration for the United States. This study has defmed the effective peak <br />velocity and acceleration with a 90 percent probability of not being exceeded in 50 years and 250 <br />years, as tabulated below. <br /> <br />TABLE 6.8 <br />PROBABILISTIe SEISMIe EVALUATION <br />Return Period 50 year 250 year <br />Probability of Exceedance in Return Period 10% 10% <br />Peak Horizontal Acceleration 0.025 g 0.10 g <br />Peak Horizontal Velocity 3 cm/s 8 cm/s <br /> <br />The seismic data presented in this section is quite comparable, especially considering the varied <br />sources referenced. In light of the seismic data presented in this section, a pseudostatic design <br />coefficient of 0.05 g is recommended, as suggested by USAeE. <br /> <br />10 <br />