Laserfiche WebLink
<br />I <br /> <br />I <br /> <br />STATE OF COLORA.DO <br /> <br />I <br /> <br />WATER DIVISION ONE <br />OFFICE OF THE STATE ENGINEER <br />Division of Water Resources <br />Department of Natural Resources <br />800 8th Avenue, Room 321 <br />Greeley, CO 80631 <br />Phone (970) 352.8712 <br />FAX (303) 659.0579 <br /> <br />Duane smith <br />1318 Webster <br />smith Geotechnical Engineers <br />Ft Collins, CO 80524 <br /> <br />March 18, 1996 <br /> <br /> <br />I <br /> <br />Roy Romer <br />Governor <br /> <br />I <br /> <br />James S. Lochhead <br />Executivc Direclor <br /> <br />I <br /> <br />RE: WOOD DAM <br />W. Div. 1, DAMID: <br /> <br />Hal D. Simpson <br />Stale Engineer <br />Richard Stenzel <br />Division Engineer <br /> <br />030338 <br /> <br />I <br /> <br />Dear Duane: <br /> <br />I <br /> <br />In reference to our phone discussion of March 12, 1996, <br />enclosed is a copy of the last inspection report and the letter <br />from the State Engineer to the company requiring that the spillway <br />be brought into compliance with the Rules and Regulations. <br /> <br />I <br /> <br />None of the reports in the last 10 years included an <br />inspection of the outlet conduit and none were critical of the <br />downstream slope or the condition of the headwall. I expect that <br />there is deterioration of the conduit, considering the age and the <br />appearance of the downstream headwall. The downstream slope at the <br />outlet section is steep and the headwall is deteriorating at least <br />on the surface. The deterioration is mitigated somewhat by the <br />conservative cross section. The performance has been satisfactory, <br />so far. However, I would caution the owners that this section of <br />the dam is critical to the long term performance and that the <br />current structure is relatively old and shows signs of <br />deterioration. Therefore, it is prudent to investigate this area <br />and consider addressing any needed rehabilitation or replacement <br />along with the spillway requirement. <br /> <br />I <br /> <br />I <br /> <br />I <br /> <br />I <br /> <br />If you have any questions concerning the report or letter, <br />please feel free to give me a call at (303) 352-8712. <br /> <br />I <br /> <br />/~;?/,1re~~~" U' . <br />i(L/:~uflu-r;/~ <br />Michael D. Cola, P.E. <br />Senior Professional Engineer II <br />W. Div. 1 - Dam Safety Branch <br /> <br />I <br /> <br />I <br /> <br />MDC\mdc\030338.tl <br />cc: State Engineer's Office <br />Shawn Hoff, Water Commissioner <br />Enclosure (a/s) <br /> <br />I <br /> <br />I <br /> <br />I <br /> <br />/ <br />