<br />I' <br /> <br />SANITARY -- It is our recommendation that a sewage collection and <br />treatment fa~lity be installed to serve the Starkvi11e area, eliminating <br />outdoor toilets, septic tanks and surface household waste flows. The <br />recommended size of plant to have an average flow of 20 gpm or 20,000 <br />gpd to serve.a population growth to 250 over the next,24 years for <br />Starkvi11e, and 48,000 gpd (35 gpm) for Starkvi11e area. <br /> <br /> TABLE 1 - STARKVILLE AREA PROJECTED NEEDS <br />Year Population Water Needs Sewage Flows <br /> gpd* gpd** <br />1976 324 32,400 162,000 32,400 <br />1980 354 35,400 177,000 35,400 <br />1985 380 38,000 190,000 38,000 <br />1990 419 41,900 209,500 41,900 <br />1995 449 44,900 224,500 44,900 <br />2000 479 47,900 239,500 47,900 <br />* Winter household only <br /> <br />** Summer peak usage with irrigation at five (5) times average <br /> <br />TABLE 2 - STARKVILLE TOWN LIMITS PROJECTED NEEDS <br /> <br />Year Population <br /> <br />Water Needs <br />gpd* gpd** <br /> <br />Average <br />Sewage Flows <br /> <br />1976 <br />1980 <br />1985 <br />1990 <br />1995 <br />2000 <br /> <br />114 <br />124 <br />136 <br />154 <br />174 <br />200 <br /> <br />11,400 <br />12,400 <br />13,600 <br />15,400 <br />17,400 <br />20,000 <br /> <br />57,000 <br />62,000 <br />68,000 <br />77,000 <br />87,000 <br />100,000 <br /> <br />11,400 <br />12,400 <br />13,600 <br />15,400 <br />17,400 <br />20,000 <br /> <br />WATER -- It is recommended that the town explore completely <br />the hookup to the Trinidad Supply System for adequate safe water. <br /> <br />#.',' <br />";- <br /> <br />- 5 - <br />