Laserfiche WebLink
<br />52 <br /> <br />. <br /> <br />Columns 14-23: Elevation (ft) (FlO.2) <br />Column 71: C (last discharge card indicator) 15 <br />Column 80: Card Type = 4 <br />The last one of the discharge-elevation cards is indicated by any <br />nonzero number in Column 71. Discharge-elevation cards only <br /> <br />need to be provided at the start of the data or where stream <br /> <br />discharge changes. Starting elevations may either be obtained <br /> <br />from field data or computed from the uniform flow equation. <br /> <br />. <br /> <br />. <br /> <br />. <br /> <br />Output <br />Output provides a table of sectional properties, generated by <br />Part 1, and a table of flow information for each station. When energy <br />conditions have been caiculated by the Standard Step Method, output <br />shows surface elevation, discharge, velocity head, friction loss in the <br /> <br />reach, eddy loss in the reach, average velocity, total head, accuracy <br /> <br />of solution, Froude number and Mannings "n" that was used. Where energy <br /> <br />levels have been computed from sectional properties, a message <br /> <br />indicating this precedes the energy information. Values for eddy loss <br /> <br />and head loss are listed as zero, since each is indeterminate by the <br /> <br />method of calculation. <br /> <br />A program listing, program variables list, sample input and <br /> <br />outputs, together with plots of cross-sections and profiles at stations <br /> <br />listed on the sample outputs, are shown in Appendices B through E. <br /> <br />. <br />