Floodplain Documents
County
Morgan
Community
Wiggins
Stream Name
Kiowa Creek
Basin
South Platte
Title
Kiowa Creek at Wiggins Flood Warning System
Date
9/1/1990
Prepared For
Wiggins
Prepared By
US Army Corps of Engineers
Floodplain - Doc Type
Floodplain Report/Masterplan
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
45
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />3. Float, switch Rod ,- Use l" diame'ter metal or PVC rod <br />approximately t,he same length as the stilling well. <br />4. Bracke,ts for mountin~, the rod in the stilling well. <br />a. Att,ach an eyebol't to the bottom of the stilling <br />well and a hose clamp to the float rod. The hose clamp, <br />resting on the eyebolt, supports the bot'tom of the rod, yet <br />allows easy removal for servicing or adjustment. <br />b. Use a "U" bolt clamp to hold the top of the rod at <br />the top at the, alarm shel te:l:'" A clamp a't the top prevents <br />the rod from rotating, yet allows for easy removal of the <br />float assembly. <br /> <br />Spare Parts for 2 gag": system. * A certain number <br />parts should be kept OIl hand to minimize the length <br />that an alarm gage is O'I~i; of service for repairs. <br />1. Ademcc, 612 Alarm DialeL (1) <br />2. Ademcc, 614-10 10 minute blank tapes. (2) <br />3. 6 Volt, 20 amp-hour GE~l Cell Batteries (2) <br />4. Consc,lidated Electric Model LS Normally Open Float <br />switches. (2) <br />5. Consolidated Electric Model LS Normally Closed Float <br />switches. (1) <br />* If only one alarm ga'::re is used, reduce this list by a <br />blank tape, a battery and a :normally open float Elwitch. <br /> <br />of <br />of <br /> <br />4.3.4 <br />spare <br />time <br /> <br />4.3.5 The most specialized of the equipment listed is <br />able in both Denver and Omaha. Other sources may <br />Known suppliers and recent price ranges are listed <br />quently: <br />4.3.5.1 Alarm Equipment <br />1. Vendors: <br /> <br />avail- <br />exist. <br />subse- <br /> <br />Carl Jar1 <br />7511 Dodgre Street <br />Omaha, Ne,braska 68114 <br />(1-402-391-5700) <br /> <br />ADI <br />Building A, unit 3 <br />700 w. Mississippi <br />Denver, Colorado 80223 <br />(303."777-1660) <br /> <br />2. Parts: (Ade,mco) <br />a. Dialer Model #612 <br />b. Dialer Programmer Model l~618 <br />c. Tape Model #613 -10 (10 minutes) <br /> <br />Price Range <br />$208.55 to $228.00 <br />$167.55 to $275.00 <br />$ 10.80 to $ 20.50 <br /> <br />4.3.5.2 Floats <br />1. Vendors: <br /> <br />MC SquarE,d <br />13205 C E:treet <br />Omaha, Nebraska 68144 <br />(1-402-333-9660) <br /> <br />canyon Systems <br />suite 305 <br />12687 W. Cedar Drive <br />Lakewood, Colorado <br />(303-987-3838) <br /> <br />14 <br />