My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
FLOOD02223
CWCB
>
Floodplain Documents
>
Backfile
>
2001-3000
>
FLOOD02223
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/25/2010 6:23:48 PM
Creation date
10/4/2006 10:42:22 PM
Metadata
Fields
Template:
Floodplain Documents
County
Arapahoe
Community
Littleton
Stream Name
Upper Slaughterhouse Gulch
Basin
South Platte
Title
Major Drainageway Planning
Date
3/1/1983
Prepared For
Littleton, Arapahoe County
Prepared By
UDFCD
Contract/PO #
&&
Floodplain - Doc Type
Floodplain Report/Masterplan
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
57
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />~~2ch A (Powers Park To Littleton City Limits) <br />Provide e!:".bankment improvements at Powers Park detention to insure it ~lOu1d <br />not breach if overtopped. The improvements should not reduce existing <br />storage. If possible. storage should be maximized. <br />2. Provide a 5-year storm sewer. <br />3. Investigate the possibility of lowering S. Delaware Street centerline crown <br />between W. Powers Avenue and W. Powers Place to provide a more efficient <br />overflow for floods larger than 5-year reocurrence frequency. <br />Reach B (Littleton Citv Limits To Grant Street) <br />1. Recommend status quo be maintained until land is redeveloped. <br />2. Recommend that redevelopment of land be in accordance with the IOO-year <br />flood plain regulations, namely no structures in the f100dway. Structures <br />outside f100dway are to be elevated above the IOO-year floodplain or an <br />adequate channel be built to convey the IOO-year flows. Any improvements <br />are to be designed as not to increase flowing to adjacent, upstream and <br />downstream properties. <br />3. A 5-year capacity low flow channel needs to be provided when the Reach C <br />improvements are to be constructed. <br />Reach C(Grant Street to Caley Avenue) <br />1. Provide a 5-year storm sewer along the alignment marked in orange on the <br />attached Exhibit map dated October 1982. <br />2. Provide for a local interceptor to Clarkson Street to connect a poorly <br />drained area to the major drainageway. (Please advise District of required <br />changes to base drawing my1ars.) <br />Reach D (Caley Avenue to Denver High1ine Canal) <br />1. Provide for a 100-year detention facility with an outlet to limit flows so <br />the proposed storm sewer capacity for Reach C is not exceeded. <br /> <br />2. Provide for the sid~ channel spillway on Highline Canal as recom~ended in <br />the High1ine Canal Master Plan, Leonard Rice Consulting Water Engineers. <br />Inc., Denver, Colorado 1975. <br />3. Caution that the detention facility needs to be constructed before the <br />Highline Canal spillway is constructed. <br />Reach E (Denver High1ine Canal to Euclid Avenue) <br />1. Provide 5-year storm sewer. <br />2. Recommend that the storm sewers recommended in the Broadway Estates <br />Subdivision Drainage Study, 1977 be implemented upstream of Reach E to <br />relieve existing drainage problems along Arapahoe Road. <br />
The URL can be used to link to this page
Your browser does not support the video tag.