<br />All requirements for reinforced concrete pipe. except those <br />referring to reinforce,ment shall apply to ncm-'reinforced concrete <br />pipe. <br /> <br />The minimum class fOl: RCP pipe shall be Class-II with flexible <br />gasket material :meet:i.ng ASTM C443 and gasket bell and spigot <br />joints. The required pipe strength shall be dete,rmined from the <br />actual depth of cover" true load, and propose,d fi.eld conditions. <br />A typical design strength calculation shall be submitted to the <br />city for approval. <br /> <br />Corrugated metal pipe may be used in parks, grl!en belts, and other <br />open space areas upon approval of the city. Where corrugated pipe <br />is intended to be used as the storm sewer pipe or culvert material, <br />the minimum gage for the pipe shall be det:ermined from Colorado <br />Department of Transpor'::ation (COOT) Standard Plan M-603-l, November <br />1, 1992, or latest edition for actual dl!pth of cover. site <br />specific calculations may be submitted utilizinq the following <br />structural design specifications: 'AASHTO - Standard Specifications <br />for Highway Bridges ... Division 0, section :";, II.STM - Standard <br />Practice for Structural Design of corrugated S'teel Pipe, pipe <br />Arches, and Arches for Storm and Sanitary S,ewl~rs and other Buried <br />Applications, ASTM A796. The minimum gage, for corrugated metal <br />pipe buried beneath railroad tracks shall be determined from <br />American Railroad En:;rineers Association spElcification, AREA - <br />Section 4.9." <br /> <br />Also, when corrugated metal pipe is intended to be used as the <br />storm sewer pipe or culvert material, site soil pH and Rrnin, <br />minimum resistivity, tests shall be performed. pH shall be <br />measured for soil and lNater. Minimum resistivity s.hall be for soil <br />and water and shall be determined in the laboratory and not in the <br />field. Corrugated aluminum pipe may be used when t.he pH is between <br />4.5 and 9.0 and Rrnin is 500 ohm-em or grea.te:r. Galvanized steel <br />corrugated pipe may be used when the pH is bE!tvTeen 5.8 and 10.0 and <br />Rrnin is 2000 ohm-em or greater. Supplemental corrosion protection <br />coatings approved by the city shall be applied to corrugated steel <br />pipe when the pH is outside the above-stated range and/or Rrnin is <br />less than 2000 ohm-em.. <br /> <br />Backfill of HDPE pipe or any flexible pipe is very critical. The <br />backfill is a major component to the structural integrity of the <br />pipe system. Bedding materials used and cOlIlpaction must have good <br />quality control for a successful pipe installation.. Bedding should <br />be at a minimum a CDOT #67 3/4-inch crushed rock, six to eight <br />inches deep under the pipe and backfilled to a foot over the pipe. <br />Design of backfill also must comply with the requirements of the <br />AASHTO Engineering Design Manual Section IS:. <br /> <br />RCP pipe and other rigid pipe systems are leSE; susceptible to <br />failure because of improper bedding and backfill procedures. <br /> <br />6-2 <br /> <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />