My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
San Juan River/Delores Division 7 Durango RICD 06CW09 Report on Design, Functionality
CWCB
>
Water Supply Protection
>
DayForward
>
7001-8000
>
San Juan River/Delores Division 7 Durango RICD 06CW09 Report on Design, Functionality
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/6/2015 3:48:31 PM
Creation date
11/10/2014 10:06:35 AM
Metadata
Fields
Template:
Water Supply Protection
File Number
06CW09
Description
Report on the Design, Functionality, and Physical Characteristics of the Durango Boating Park as it Relates to the RICD Application
State
CO
Basin
San Juan/Dolores
Water Division
7
Date
2/15/2006
Author
Recreation Engineering and Planning 485 Arapahoe Ave Boulder, CO 80302 Gary M. Lacy, P.E.
Title
Report on the Design, Functionality, and Physical Characteristics of the Durango Boating Park as it Relates to the RICD Application
Water Supply Pro - Doc Type
Report/Study
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
51
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
r <br />a <br />0 <br />N <br />A <br />U <br />C <br />High and Low flow design <br />-80 -60 -40 -20 0 20 40 60 80 <br />Lateral Station (width) <br />Figure 15. Approximate geometry of the U- Structures proposed for the lower reach of the <br />Boating Park (Tease note that the overbank geometry is for illustrative purposes only). <br />This type of design creates critical flow at the crest of the control structure and captures, <br />controls and diverts the flows of the river for a variety of flows. Other similar structures <br />have been found to capture, control and divert flows across similar ranges of flows as are <br />expected in the Animas. Furthermore, these types of structures have been implemented in <br />similar rivers without creating an impact to the 100 year flood plain. These structures are <br />being designed, using the HEC-RAS software, to ensure that there will be no net negative <br />effect to the floodplain. It can be concluded from Figures 14 and 15 that the structures on <br />the upper reach of the boating park can capture, control and divert the flows of the Animas <br />River up to 1400 cfs. The lower structures will be able to capture control and divert the <br />flows of the Animas River up to flows of 1800 cfs, and, at flows of 900 cfs, will capture, <br />control, and divert while providing for the City's intended purpose. Due to the low and high <br />flow geometry these Structures are designed to function well during a range of flows. <br />33 <br />`e. <br />C. <br />High Flow <br />0 <br />Low Flow <br />-80 -60 -40 -20 0 20 40 60 80 <br />Lateral Station (width) <br />Figure 15. Approximate geometry of the U- Structures proposed for the lower reach of the <br />Boating Park (Tease note that the overbank geometry is for illustrative purposes only). <br />This type of design creates critical flow at the crest of the control structure and captures, <br />controls and diverts the flows of the river for a variety of flows. Other similar structures <br />have been found to capture, control and divert flows across similar ranges of flows as are <br />expected in the Animas. Furthermore, these types of structures have been implemented in <br />similar rivers without creating an impact to the 100 year flood plain. These structures are <br />being designed, using the HEC-RAS software, to ensure that there will be no net negative <br />effect to the floodplain. It can be concluded from Figures 14 and 15 that the structures on <br />the upper reach of the boating park can capture, control and divert the flows of the Animas <br />River up to 1400 cfs. The lower structures will be able to capture control and divert the <br />flows of the Animas River up to flows of 1800 cfs, and, at flows of 900 cfs, will capture, <br />control, and divert while providing for the City's intended purpose. Due to the low and high <br />flow geometry these Structures are designed to function well during a range of flows. <br />33 <br />
The URL can be used to link to this page
Your browser does not support the video tag.