Animas -La Plata Project <br />Feb 13, 2013 Draft Transfer Inspection Report <br />5. 48" Sleeve Valve <br />The 48" sleeve valve is used to make normal operational releases into Basin Creek and to <br />drain the penstock. Flows may be adjusted by the electric motor operator at the ACP or <br />locally at the valve. A 48" butterfly valve is installed upstream of the sleeve valve and is <br />used for isolation. The sleeve valve was chosen to ensure that non - native fish escapement <br />to the Animas River is prevented. <br />During Project releases, this valve will normally be operated by SCADA. The Sleeve Valve <br />potentiometer was replaced and programmed in November 2012. <br />TRANSFER ISSUE <br />STIPULATION <br />Fish mortality - related <br />Reclamation will continue to work with the Recovery Program to <br />constraints associated with <br />ensure that concerns related to potential fish escapement have <br />operational Project releases <br />been alleviated. <br />need to be resolved <br />6. Durango M &I Line <br />The Durango M &I supply line is for future water development and consists of the 36" <br />diameter steel pipe and a 36" diameter motor operated butterfly valve. The end of the pipe <br />terminates at a 36" diameter blind flange beneath the ground surface near the control <br />house. <br />TRANSFER ISSUE <br />STIPULATION <br />Coating on the bypass line is <br />Reclamation will repair the coating on the 8 „ bypass line. <br />damaged <br />7. Ultrasonic Flowmeter <br />The ultrasonic flowmeter (Accusonic 7510 +) feed - through transducer assemblies is installed <br />on the 66” diameter steel outlet works discharge pipe. The flowmeter console is installed in <br />the control building. The flowmeter is used to measure the flow in the pipe and provide <br />display readouts of the flowrate in units of cfs, and of totalized volume in units of acre -feet. <br />The system is configured to measure flow in fully surcharged pipes and conduits and was <br />factory certified in 2012. The manufacturer provided training to the Association in March <br />2012. Accusonic has stated that noise coming from the unit is normal, even though the two <br />older units (Accusonic 7510) in the Durango Pumping Plant run quiet. <br />TRANSFER ISSUE <br />STIPULATION <br />Flowmeter software is out <br />Reclamation will install new Accusonic software. <br />of date <br />8. Auxiliary Control Panel <br />Auxiliary Control Panel (ACP) control power is provided by a 120 -volt branch circuit from <br />lighting and distribution panel board DJA. All gate and valve controls and indicating devices <br />are located or interfaced at the auxiliary control panel, and have been calibrated. <br />Transferred Works Inspection 7 Animas -La Plata Project <br />