My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
C150227 Final Report
CWCB
>
Grants
>
DayForward
>
C150227 Final Report
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/27/2013 7:43:05 AM
Creation date
3/26/2013 1:12:58 PM
Metadata
Fields
Template:
Grants
Applicant
South Platte Ditch Company
Grant Type
Non-Reimbursable
Fiscal Year (i.e. 2008)
2006
Project Name
Canal Modernization and Radio Telemetry Demonstration Project
CWCB Section
Finance
Contract/PO #
C150227
Grants - Doc Type
Final Deliverables
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
70
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
REGWRITE 4498,22999 <br />REM set starting address in log buffer <br />REGWRITE 4497,7100 <br />REM first time through flag =0 <br />REGWRITE 4496,0 <br />REM expansion /future register use <br />REM possible # of minutes between <br />REM for this prog, 4495 is number <br />REM updates. <br />REGWRITE 4495,20 <br />REM master A -E tail pointers <br />REGWRITE 4494,REGREAD(4499) <br />REGWRITE 4493,REGREAD(4499) <br />REGWRITE 4492,REGREAD(4499) <br />REGWRITE 4491,REGREAD(4499) <br />REGWRITE 4490,REGREAD(4499) <br />updates <br />of secs between <br />REM initialize setup registers <br />REM set analog inputs mode: (0= voltage, 1= current) <br />REM CD100 requires setting current mode via jumpers <br />REM on left side of pcb. <br />REM Jumpers must be installed for current mode (default) <br />REM and removed for voltage mode. <br />REM analog channel 1 is bottom most jumper (nearest <br />REM terminals) and chan 6 is top most. <br />REGWRITE 4819,3 <br />REM set analog inputs scaling: <br />REM 0= 0- 20ma /0 -5v, 1= 4- 20ma /1 -5v <br />REM Analog Channel- All AI2 AI3 AI4 AI5 AI6 <br />REM Binary Value -- 1 2 4 8 16 32 <br />REGWRITE 4820,3 <br />REM * initialize program floating point operating regs <br />REM NOTE: these values are set for 2 flumes, flume 1 first <br />REM set sensor slope register values <br />REGWRITE 7033,0.002817 <br />REGWRITE 7034,0.001221 <br />REM set sensor offset register values <br />REGWRITE 7037,0.0049 <br />REGWRITE 7038,0 <br />REM set sensor calibration factors <br />REGWRITE 7039, -5.9 <br />REGWRITE 7040,1 <br />REM set multiplier <br />REGWRITE 7041,20.021 <br />REGWRITE 7042,0 <br />REM set correction <br />REGWRITE 7043,0 <br />REGWRITE 7044,0 <br />(sensor 1 K1, sensor 2 K1) <br />(sensor 1 K2, sensor 2 K2) <br />REM set exponent (sensor 1 U1, sensor 2 U1) <br />REGWRITE 7045,1.5876 <br />23 <br />
The URL can be used to link to this page
Your browser does not support the video tag.