Laserfiche WebLink
<br />Pa ge 41 <br /> <br />resolution table of variables. The listing will include particle <br />concentrations and liquid water contents derived from the FSSP <br />and 1D probes and a simple count of records from the 2D-C and <br />2D-P probes during the 10-second interval to verify the working <br />of these sensors. The listing will be reviewed for the <br />reasonableness of the values by the Bureau site coordinator. <br /> <br />The tapes will be sent to the Montrose office as soon as possible <br />for standard processing of the flight data. Any further problems <br />that are then discovered will be immediately communicated to <br />Prescott. <br /> <br />Data from the microwave radiometer will be quality checked in the <br />field using the strip chart paper or listings. Tipping curves <br />will be performed about weekly, as weather permits, to maintain <br />quality calibrations. The disks of data will be periodically <br />(about weekly) copied to magnetic tape during clear sky episodes <br />to minimize loss of liquid water data. The tapes will then be <br />sent to Montrose. There they will be copied into the P-E <br />(Perkin-Elmer) computer data base from which daily graphs of the <br />liquid and vapor will be made and examined. <br /> <br />Data from the radar will be recorded on magnetic tape and will be <br />sent to Montrose about weekly as a minimum. There time-height <br />