Laserfiche WebLink
<br />SENT BY: BOR-WCAOS SO <br /> <br />" <br /> <br />. <br /> <br />2 -1 7 - 99 1 3: 00 ; <br /> <br />970 385 6539 => <br /> <br />303 866 4474; <br /> <br />#12/12 <br /> <br />C. SPECIAL REPORTING DURING FLOOD OR HIGH VATER CONDITIO~S <br /> <br />Flooding Is any event which would cause ehe reservoir Water surface elevacion eo <br />exceed 7665 feet or releases co exceed 2,500 cf.. If eieher sieuation appears to be <br />1l1111linent:, the Reservoir Superintendene must 111l11l8diately implement the flood <br />proeedures in the Emergency Action Plan and notify the Durango Projects Office. <br /> <br />High water condieions are periods when; <br /> <br />1. The reservoir storage is greater than the Corps of Engineers Flood Concrol <br />Regulations allowable storage for the current inflow forecast. <br /> <br />2. It 1s apparent that the reservoir elevatlon will go above elevation 7664.5. <br /> <br />The Reservoir Superintendent normally report~ reservoir daca once per week to the <br />Durango Projects Office. During high water conditions. reservoir data will be <br />reported a~ least daily to the Durango Projects Office Vater Operations Branch. The <br />daca reported will include: reservoir elevation, inflow, precipitation. maximum and <br />minimum temperaCure, and pan evaporation. The Duranlo Projects Office Yater <br />Operations Branch will be responsible for revIewing cbe high water conditions and <br />foreeasced weather co recommend appropriace acciona Co be caken by the Re.erv01r <br />Superincendenc. <br /> <br />Use of surcharge capacity above water surface elevacion 7665 is reserved for <br />emergency si~uatlons or extreme conditions on ehe reservoir or river basin. <br />Surcharge will be used to seore inflow from specific hydrologic flood evancs which <br />if released, would exceed 2,500 cf. in the Pine River. If surcharge capacicy is <br />used, the Reservoir Superintendenc is to notify the Durango Projects Office <br />immediately. The Emergency ACtion Plan procedur.. for flooding will be implemented. <br />Surcharge scorage will be considered temporary and the Pine RIver vill be required <br />to flow at a minimum of 2.'00 cfs as long as there is available reservoir surcharge. <br />the spillway radial gaees will be operated in accordance with the requirements of <br />Drawing No. 191-0-568, Appendix D. <br /> <br />The dam will be coftl:lnuously attended durinc flooding or hlah W.Cer concU.elona or <br />use of surcharge capacit:y. The frequency of visiting the dam to monieor conditions <br />vill be determined on a ~ase by case ~a~is after consuleing with the Durango <br />Projeces Office. _~"" ~" <br /> <br />i/"' <br /> <br />."" <br />.# to',':' <br /> <br />\ <br /> <br />111-8 <br /> <br />Revised 03/94 <br /> <br />