My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
PROJ02105
CWCB
>
Loan Projects
>
DayForward
>
0001-1000
>
PROJ02105
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/19/2009 11:06:27 AM
Creation date
7/17/2007 7:50:29 AM
Metadata
Fields
Template:
Loan Projects
Contract/PO #
FS0065FX
Contractor Name
Greeley and Loveland Irrigation Company
Contract Type
Loan
Water District
0
County
Larimer
Loan Projects - Doc Type
Feasibility Study
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
113
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
Show annotations
View images
View plain text
<br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br />I <br /> <br />Chapter III - Background Information <br /> <br />downstream 36-inch CMP is not a dam safety concern, the pipe is collapsing and prevents efficient <br />delivery of waters, which the Company regularly uses as part of an exchange with the City of <br />Loveland. Additionally, a hydraulic analysis indicates that SED requirements of draining the top 5 <br />feet of the reservoir in 5 days (see section F.l, Flood Hydrology) cannot be met. Photographs of the <br />low-level outlet works and reservoir are included in Appendix A. <br /> <br />D. Water Demands <br /> <br />The scope of this project includes the replacement of the existing low-level outlet works with <br />an efficient operating structure. No additional water supplies will be developed in connection with <br />this project. No new or increased diversions will be made and no additional storage capacities will <br />be created. The use of the water will not change as a result of this project. The project will not <br />increase the Company's water storage or supply. <br /> <br />E. Project Lands <br /> <br />The Greeley and Loveland Irrigation system will not change as a result of this project. This <br />project will not broaden the Company service area and will not provide for the irrigation of any new <br />lands. <br /> <br />F. Hydrology and Water Rights <br /> <br />F.l Flood Hydrology <br /> <br />Flood hydrology is not required to size the outlet system. The outlet system must be designed <br />per rule 5 .A.(7)( d)(I) of the "Rules and Regulations for Dam Safety and Dam Construction" which <br />states: "The outlets for Class I dams shall be capable of releasing the top five feet of the reservoir <br />capacity in five days... In addition, outlets shall be capable of passing inflow to the reservoir with a <br />minimum of 10 feet of head, in order to meet the demands of downstream senior water rights, and <br />the owner's release requirements." <br /> <br />As mentioned in Section C of this chapter, the existing system does not meet SED <br />requirements; draining the top five feet of the reservoir in five days. Combining the existing pumps, <br />high-level diversion structure, and the low-level outlet works, it would take approximately ten days <br /> <br />6.-ts" <br />!Au i <br />~~ <br /> <br />10 ~f <br /> <br />Boyd Lake Dam Outlet System Feasibility Study . <br /> <br />8 <br /> <br />1f30VLE <br />
The URL can be used to link to this page
Your browser does not support the video tag.