Laserfiche WebLink
<br />Peak discharge-drainage area relationships for the streams studied by detailed methods are <br />shown in Table 4, "Summary of Discharges." <br /> <br />3.2 Hydraulic Analyses <br /> <br />Analyses of the hydraulic characteristics of flooding from the sources studied were carried out <br />to provide estimates of the elevations of floods of the selected recurrence intervals. Users <br />should be aware that flood elevations shown on the FIRM represent rounded whole-foot <br />elevations and may not exactly reflect the elevations shown on the Flood Profiles or in the <br />Floodway Data tables in the PIS report. Flood elevations shown on the FIRM are primarily <br />intended for flood insurance rating purposes. For construction and/or floodplain management <br />purposes, users are cautioned to use the flood elevation data presented in this FIS in <br />conjunction with the data shown on the FIRM. <br /> <br />Water-surface elevations (WSELs) of floods of the selected recurrence intervals for all steams <br />studied by detailed methods with the exception of the South Platte River, were computed <br />using the USACE HEC-2 step-back water computer program (Reference 53). <br /> <br />For the South Platte River, the WSELs of floods of the selected recurrence intervals were <br />computed using the NRCS WSP2 computer program (Reference 54). These profiles and <br />elevations were compared with historic floods, and the flood stages were then determined. <br /> <br />City of Arvada <br /> <br />The basis of the hydraulic analysis utilized is from the Major Drainageway Planning Report <br />and from the UDFCD plans entitled "Ralston Creek Flood Hazard Area Delineation Study" <br />(Reference 55). <br /> <br />City of Edgewater <br /> <br />The drainageway between Depew Street and Sheridan Boulevard was studied to provide <br />estimates of the elevation of the lOO-year flood. For the HEC-2 program, topographic data <br />were taken from a topographic map with 1.0 foot contour intervals prepared by Greiner <br />Engineering Sciences, Inc. and checked to ensure conformance with mapping standards <br />(Reference 56). Field surveying was also conducted by Wright Water Engineers. From this <br />topographic map, a total of 15 cross sections were digitized and used as data for the computer <br />analysis. An analysis of flow in the stormwater channel between Ingalls Street and Depew <br />Street is based on the Manning's Equation to estimate normal depth. A step-backwater <br />analysis was used where necessary to reflect obstructions, such as culverts. Where bends <br />occur in the channel, superelevation of the flow has been calculated and included in the <br />WSELs. Culverts have been analyzed to determine the control condition, inlet or outlet <br />control. <br /> <br />Because of irregular and poorly defined channels for street and overland flows in the area <br />upstream on Ingalls Street and 20th A venue, the resulting 1 DO-year floodplain for this area is <br />not as well defined. Updated aerial mapping was used to determine "channel" cross sections <br />and WSELs in this area. <br /> <br />30 <br />