<br />Richartl D. Lamm <br />Governor <br />DATE <br />70: <br />III IIIIIIIIIIIII III <br />DEPARTMENT OF NATURAL RESOURCES <br />Davitl H. Getches. Executive Director <br />MINED LAND RECLAMATION DIVISION <br />DAVID C. SHELTON, Director <br />March 3, 1986 <br />Peter O'Connor <br />FROM; Anne Baldrige ~ ~/ <br />RE: BLUE FLAME - ADEQUACY REVIEW REGARDING SURFACE DRAINAGE <br />I have completed my review of the proposed drainage control system for this <br />mine. Following are my comments. <br />1. The design for the propoed pond is adequate, however, the pond is <br />circular and would be difficult to build. I suggest building a square pond <br />with the same depth and side slopes. The surface dimensions should be 50' x <br />50' with inside bottom dimensions of 46' x 46'. <br />2. The pond design does not include a principal or emergency spillway. A <br />principal spillway is not necessary for this small pond as long as the <br />operator commits to pumping the pond to maintain enough storage for the 10 <br />year - 24 hour storm. <br />The pond should have an emergency spillway. This spillway must be designed tc <br />pass the peak flows from the 25 year - 24 hour storm event. Using the <br />criteria established for the 10 year - 24 hour storm the design is as follows. <br />L = 320 ft. <br />Z=100 ft. <br />5=31% <br />A = 1.9 acres <br />Rainfall = 2.5" <br />CN=81 <br />Runoff = 0.94" <br />No shape adjustment <br />Slope Adjustment = 1.09 <br />Q 25 years = (1.09)(4.83 CFS/in)(0.94") <br />Spillway Design: <br />n <br />i~ ~ t <br />I`- ~ --~I <br />= 4.95 CFS <br />determine L using <br />broad-crested weir: <br />Q = CLH 3/2 <br />423 Centennial Building, 1313 Sherman Street Denver, Colorado 80203 Tel. (303) 866-3567 <br />