My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2018-01-12_REVISION - M2000041 (26)
DRMS
>
Day Forward
>
Revision
>
Minerals
>
M2000041
>
2018-01-12_REVISION - M2000041 (26)
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
6/16/2021 6:21:08 PM
Creation date
1/16/2018 1:38:31 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M2000041
IBM Index Class Name
Revision
Doc Date
1/12/2018
Doc Name Note
MAP: Sheet 9 of 11
Doc Name
Adequacy Review Response #2
From
Fremont Paving & Redi-Mix
To
DRMS
Type & Sequence
TR4
Email Name
ERR
WHE
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
Page 1 of 1
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
z <br />w <br />SPREAD EXCESS TRENCHED AND 6' STEEL "T" POST IN CENTER OF SLURRY WALL <br />BACK FILL MATERIAL TO THE PIT TO IDENTIFY CENTERLINE OF AS -CONSTRUCTED <br />SIDE OF THE RESERVOIR. ALIGNMENT. MAXIMUM SPACING 100' ON CENTER AND <br />ALL ANGLE POINTS OR POINTS OF TANGENCY <br />10' 3' 3' 3' <br />3 1 1' (NOMINAL) <br />NOTES: <br />1. CAP SHALL BE CONSTRUCTED, WITH 'T' POST INSTALLED AS REQUIRED <br />WITHIN 200' OF THE ACTIVE BACKFILL MIXING AREA. <br />2. CAP MAY REQUIRE LOCAL FIELD ADJUSTMENT TO MEET FINAL GRADING <br />PLAN REQUIREMENTS, AS NECESSARY, TO MEET PROJECT INTENT. <br />3. AFTER PRIMARY CONSOLIDATION OF THE SLURRY WALL, FINE GRADING <br />CAP MATERIAL SHALL BE GRADED BY THE OWNER TO PROVIDE A CROWN <br />ON EITHER SIDE OF THE CENTERLINE AT A SLOPE BETWEEN OF 0.25" TO <br />0.5" PER FOOT. <br />4. REMOVE SLURRY WALL CAP IN SPILLWAY AREA. <br />4.5' <br />SLOPE 3:1 OR <br />FEATHER AT FLATTER <br />SLOPES AS <br />NECESSARY <br />o p O o co 00 0 <br />0 0 0 0 0 p O <br />O O p 0 O G <br />TOP OF EXISTING <br />WORKING PLATFORM <br />CLAYEY SOIL <br />SOIL BENTONITE <br />BACKFILL <br />SLURRY WALL TRENCH CAP DETAIL <br />19' <br />18" CRUSHED ROCK <br />1' CLASS 5 ROADBASE <br />o p o O <br />O <br />- FILTER CLOTH & GEOGRI <br />FABRIC (AASHTO CLASS <br />NONWOVEN SEPARATIOI <br />FABRIC & TENSAR 1600 <br />OR EQUIVALENT) OR 0.5" <br />STEEL PLATE <br />SOIL BENTONITE <br />BACKFILL <br />0 3 6 <br />Scale In Feet <br />O - C:> c <br />O o 0 <br />O <br />O <br />SUPPLEMENTAL FINES 75% <br />CY/LF <br />( ) <br />O <br />o <br />o <br />p <br />0 <br />O <br />O <br />O <br />n r� <br />14+00 to 20+00 <br />1.1 <br />109.2 30 ft/bag <br />20+00 to 40+00 <br />1.1 <br />124.8 25 ft/bag <br />TOP OF SLURRY WALL <br />@ TOP OF EXISTING <br />WORKING PLATFORM <br />PERMANENT ROAD CROSSING DETAIL <br />0 3 6 <br />Scale In Feet <br />QUANTITY FINES SUPPLEMENTS AND BENTONITE SPACING <br />(1% APPLICATION RATE) <br />STATION RANGE <br />SUPPLEMENTAL FINES 75% <br />CY/LF <br />( ) <br />DRY BENTONITE SPACING BETWEEN <br />ADDITION RATE <br />(LB/FT) EACH 3,000 LB BAG <br />0+00 to 8+00 <br />1.1 <br />109.2 30 ft/bag <br />8+00 to 14+00 <br />1.1 <br />124.8 25 ft/bag <br />14+00 to 20+00 <br />1.1 <br />109.2 30 ft/bag <br />20+00 to 40+00 <br />1.1 <br />124.8 25 ft/bag <br />40+00 to 46+00 <br />1.1 <br />109.2 30 ft/bag <br />46+00 to 49+00 <br />1.1 <br />124.8 25 ft/bag <br />49+00 to 65+00 <br />1.1 <br />109.2 30 ft/bag <br />65+00 to 70+00 <br />1.1 <br />124.8 25 ft/bag <br />70+00 to 75+88 <br />1.1 <br />109.2 30 ft/bag <br />1. TABLE BASED ON SUPPLEMENTAL FINES WITH AN AVERAGE OF <br />75% PASSING THE #200 SIEVE. <br />2. RATES SHOWN ARE FOR A MINIMUM OF 30% PASSING #200 SIEVE <br />FOR BACKFILL AND MAY REQUIRE ADJUSTMENT. <br />3. BAG SPACING BASED ON A DRY BENTONITE APPLICATION RATE OF <br />1% AND MAY BE ADJUSTED BASED ON THE FINAL MIX DESIGN <br />PREPARED BY THE DESIGNER/ENGINEER AND THE MINIMUM OF <br />FINES PASSING #200 SIEVE AS APPROVED BY DESIGN ENGINEER. <br />4.5' <br />SLOPE 3:1 OR <br />FEATHER AT FLATTER <br />SLOPES AS <br />NECESSARY <br />0 0 0 v O <br />0 <br />o in O co <br />O O O r- O CV p <br />3� <br />NOTE: <br />ROAD CROSSING CONSTRUCTION, <br />IF NECESSARY, WILL BE DIRECTED <br />BY THE OWNER. <br />EXISTING SLURRY WALL <br />WORKING PLATFORM <br />70' TYP <br />(45' MIN) <br />45' <br />(30' MIN) <br />2.5' <br />BACKFILL MIXING AREA (MIN) <br />STOCKPILED SUPPLEMENTAL FINES <br />25' <br />(15' MIN) <br />MAINTAIN SLURRY <br />LEVEL WITHIN 2' OF <br />GROUND SURFACE, <br />OVERBURDEN <br />SLURRY WALL <br />WORKING PLATFORM <br />MSHA SAFETY BERM <br />� (SEE DETAIL) <br />FINAL RECLAMATION <br />�N. Ii, Z SLOPE <br />TOP OF WORKING <br />PLATFORM <br />r .7 <br />=2.5 y'V <br />MSHA SAFETY BERM DETAIL <br />0 3 6 <br />Scale In Feet <br />NOTES: <br />1. SAFETY BERM MUST BE CONSTRUCTED TO A HEIGHT <br />GREATER THAN OR EQUAL TO HALF THE WHEEL HEIGHT OF <br />THE LARGEST WHEELED PIECE OF MOBILE EQUIPMENT=2.5' <br />D ii °! �� 101 r <br />2 2�! <br />
The URL can be used to link to this page
Your browser does not support the video tag.