Laserfiche WebLink
King Mine buildings on the Bowie property. Historic rock retaining walls for slope <br />protection of the former rail lines appear to be in good condition and performing well <br />with no failures noted during our visit. The ditch appears to be graded to allow water <br />flow downslope to established drainages and the slope above the ditch is beginning to <br />achieve its natural angle of repose. We do not recommend any additional slope <br />protection measures at this time, since erosion blankets and seeding are unlikely to <br />perform well in the coal fines that make up the slope composition. The ditch should be <br />inspected and cleaned periodically as the slope naturally vegetates itself to match <br />existing conditions above. Any significant slope failures or changes in conditions should <br />be brought to our attention for possible mitigations recommendations. <br />3. In general, the grading and compaction of CWDA No. 2 appears to be progressing well <br />and significant work has been done since our last site visit on March 25, 2103, as <br />indicated by our weekly compaction testing and observation reports. <br />Closina <br />On -going monitoring of inclinometers and piezometers at CWDA No. 2 provides an indication of <br />the stability of the refuse as well as an indication of probable performance for other refuse piles <br />at Bowie. For these reasons, we recommend continued monitoring of this instrumentation on a <br />quarterly basis. We sincerely appreciate the opportunity to work with you on this project. If <br />you have any questions regarding this letter or the instrumentation monitoring at CWDA No. 2, <br />please don't hesitate to contact me at (970) 497 -8852 ordan(Fabuckhornaeo.crrn. <br />Sincerely, <br />BUCKHORN GEOTECH, INC. r,`�.•,' c��. �� `, <br />Ga"�' <br />Daniel C. Quigley, P.E. <br />SS'l0 N N\- <br />Enclosures: Instrumentation Site Plan, Inclinometer Cumulative Displacements, Summary of Pore <br />Pressure Monitoring <br />cc: Jim Stover, J.E. Stover and Associates — ELECTRONICALLY ONLY <br />2nd Qtr Monitoring Report.doc PN #05- 126 -GEO <br />Page 3 of 4 <br />