My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013-05-21_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2013-05-21_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:20:37 PM
Creation date
5/22/2013 7:51:37 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
HYDROLOGY
Doc Date
5/21/2013
Doc Name
First Quarter 2013 Groundwater Sampling
From
Golder Associates
To
DRMS
Permit Index Doc Type
Hydrology Report
Email Name
ECS
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
34
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
AOZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Spnngs, CO 80487 (800) 334 -5493 <br />Golder Associates ACZ Project ID: L11197 <br />L11197 -01 WG340820 Manganese, dissolved <br />M200 7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level The recovery of the associated control sample (LCS <br />or LFB) was acceptable <br />WG341037 Chloride <br />M300 0 - Ion Chromatography <br />DC <br />Sample required dilution Non - target analyte exceeded <br />calibration range <br />WG341070 Fluoride <br />SM450OF -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG340929 pH <br />SM4500H+ B <br />ZW <br />Method deviation The sample was centrifuged prior to <br />analysis due to high solid content <br />WG340923 Residue, Filterable (TDS) @180C <br />SM2540C <br />ZO <br />Concentration is based on a final residue greater than 200 <br />mg <br />WG340929 Total Alkalinity <br />SM2320B - Titration <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 1 Ox MDL) <br />SM2320B - Titration <br />ZW <br />Method deviation The sample was centrifuged prior to <br />analysis due to high solid content <br />L11197 -02 WG340820 Manganese, dissolved <br />M200 7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level The recovery of the associated control sample (LCS <br />or LFB) was acceptable <br />WG341070 Fluoride <br />SM450OF -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG340929 pH <br />SM4500H+ B <br />ZW <br />Method deviation The sample was centrifuged prior to <br />analysis due to high solid content <br />WG340923 Residue, Filterable (TDS) @180C <br />SM2540C <br />ZO <br />Concentration is based on a final residue greater than 200 <br />mg <br />WG341037 Sulfate <br />M300 0 - Ion Chromatography <br />DC <br />Sample required dilution Non - target analyte exceeded <br />calibration range <br />WG340929 Total Alkalinity <br />SM2320B - Titration <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />SM2320B - Titration <br />ZW <br />Method deviation The sample was centrifuged prior to <br />analysis due to high solid content <br />L11197 -03 WG340820 Barium, dissolved <br />M200 7 ICP <br />M3 <br />The spike recovery value is unusable since the analyte <br />concentration in the sample is disproportionate to the spike <br />level The recovery of the associated control sample (LCS <br />or LFB) was acceptable <br />WG341070 Fluoride <br />SM450OF -C <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG341153 Sulfate <br />M300 0 - Ion Chromatography <br />DC <br />Sample required dilution Non - target analyte exceeded <br />calibration range <br />M300 0 - Ion Chromatography <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG340929 Total Alkalinity <br />SM2320B - Titration <br />RA <br />Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />REPAID 15.06 05.01 <br />Page 20 of 26 <br />
The URL can be used to link to this page
Your browser does not support the video tag.