Laserfiche WebLink
AZ Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Rio Grande Silver, Inc. <br />ACZ ID WORRNU <br />METHOD Ct M. DESCRIPTION <br />L11060 -03 WG340476 Arsenic (1312) <br />WG340577 Barium (1312) <br />WG340476 Beryllium (1312) <br />WG340729 Boron (1312) <br />WG340476 Cadmium (1312) <br />REPAD.15 06 05.01 <br />M6020 ICP -MS <br />M6010B ICP <br />norganic Extended <br />Qualifier Report <br />ACZ Project ID: L11050 <br />B7 Target analyte detected in prep / method blank at or above <br />acceptance limit Sample value is > 10X the concentration <br />in the method blank <br />BA Target analyte detected in prep / method blank at or above <br />acceptance limit Sample value is > 20X the concentration <br />in the method blank <br />M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6020 ICP -MS ZB The ICP -MS Serial Dilution was not used for data validation <br />because the sample concentration was less than 100 times <br />the MDL. <br />WG340729 Calcium (1312) M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL <br />WG340442 Cobalt (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG340757 Copper (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6020 ICP -MS ZB The ICP -MS Serial Dilution was not used for data validation <br />because the sample concentration was less than 100 times <br />the MDL <br />WG340577 Iron (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG340757 Lead (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG340729 Magnesium (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG340442 Manganese (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG340362 Mercury (1312) M7470A CVAA RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG340442 Molybdenum (1312) M60108 ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Nickel (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Potassium (1312) M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL <br />WG340476 Selenium (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />WG340442 Silica (1312) M60108 ICP ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL. <br />WG340476 Silver (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Thallium (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />Uranium (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />Page 33 of 38 <br />