Laserfiche WebLink
A Z Laboratories, Inc. <br />2773 Downhill Drive Steamboat Springs, CO 80487 (800) 334 -5493 <br />Rio Grande Silver, Inc. <br />ACE ID WORKNUM PARAME TER <br />METHOD Q1»TAL `; DESCRIPTION <br />L11050 - WG340757 Arsenic (1312) <br />WG340729 Barium (1312) <br />WG340476 Beryllium (1312) <br />WG340729 Boron (1312) <br />WG340476 Cadmium (1312) <br />REPAD.15.06 05 01 <br />M6020 ICP -MS <br />M6020 ICP -MS <br />Inorganic Extended <br />Qualifier Report <br />ACZ Project ID: L11050 <br />RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />ZB The ICP -MS Serial Dilution was not used for data validation <br />because the sample concentration was less than 100 times <br />the MDL <br />M6010B ICP RD For a solid matrix, the duplicate RPD (spike or matrix) <br />exceeded the control limit, which is attributable to the non - <br />homogeneity of the sample <br />M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL <br />M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL). <br />M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6020 ICP -MS ZB The ICP -MS Serial Dilution was not used for data validation <br />because the sample concentration was less than 100 times <br />the MDL. <br />WG340577 Calcium (1312) M6010B ICP BA Target analyte detected in prep / method blank at or above <br />acceptance limit Sample value is > 20X the concentration <br />in the method blank <br />WG340442 Cobalt (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG340757 Copper (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6020 ICP -MS ZB The ICP -MS Serial Dilution was not used for data validation <br />because the sample concentration was less than 100 times <br />the MDL <br />WG340442 Iron (1312) M6010B ICP BF Target analyte in prep / method blank at or above the <br />acceptance criteria. Target analyte was not detected in the <br />sample [< MDL] <br />M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL <br />WG340757 Lead (1312) M6020 ICP -MS RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG340442 Magnesium (1312) M6010B ICP BF Target analyte in prep / method blank at or above the <br />acceptance cnteria Target analyte was not detected in the <br />sample [< MDL]. <br />M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />M6010B ICP ZG The ICP Serial Dilution was not used for data validation <br />because the sample concentration was less than 50 times <br />the MDL. <br />Manganese (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG340362 Mercury (1312) M7470A CVAA RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />WG340442 Molybdenum (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />validation because the sample concentration is too low for <br />accurate evaluation (< 10x MDL) <br />Nickel (1312) M6010B ICP RA Relative Percent Difference (RPD) was not used for data <br />Page 27 of 38 <br />