Laserfiche WebLink
• <br />• <br />• <br />EXISTING POSTMINE CHANNEL <br />3:1 OR-FLATTER <br />LIMITS OF EXCAVATION <br />1"1 <br />4 4 MAX. 8' <br />I <br />FRONT VIEW <br />6' DIAMETER PIPE <br />AX 10' <br />SPILLWAY <br />n5'5• 2.5 <br />III 1 2.5 <br />KEYWAY J) <br />10' <br />PROFILE VIEW <br />EXISTING GROUND <br />TR -67 09 -22 -09 <br />9' ROCK ENERGY <br />DISSIPATER AT OUTFALL <br />TOP VIEW <br />I <br />i <br />i <br />i <br />/D' ROCK ENERGY <br />ISSIPATER AT OUTFALL <br />EXISTING POSTMINE CHANNEL <br />i <br />I <br />ORIGINAL CONTOURS <br />PLAN VIEW V <br />• STRUCTURE CAPACITY <2 ACRE —FEET ®iSEP X200 <br />vision 9 <br />• EMBANKMENT — s 81 FEET HIGH il/lInin9 and Sa ea on, <br />— COMPACTED FILL <br />— KEYWAY 3' X 10' COMPACTED <br />I <br />• SPILLWAY — CONSTRUCTED TO SAME DIMENSIONS AS POSTMINE CHANNEL <br />(SEE APPENDIX 13 -12.3) <br />• 2 — 6 INCH PIPES INSTALLED TO PROVIDE STRUCTURE DEWATERING <br />(OPEN END T WITH SLOTTED RISER ATTACHED TO EACH PIPE) <br />• EMBANKMENT WILL BE TOPSOILED <br />• EMBANKMENT WILL BE SEEDED WITH A MESIC DRAINAGE SEED MIX <br />• EACH STRUCTURE WILL BE FIELD FIT <br />i <br />S E^'E <br />Coal Company <br />PROJECT- <br />SCALE SENECA II —W MINE <br />10 0 ` 10 20 DRAWING nT <br />TYPICAL <br />RUNOFF CONTROL STRUCTURE <br />GSM-- MG\A— .,ORaaa3n 1- 10\Y0ASATMMCM7M".d" r n . <br />