Laserfiche WebLink
• <br />PIPE CULVERT ANALYSIS <br />COMPUTATION OF CULVERT PERFORMANCE CURVE <br />February 4, 1991 <br />SENECA II-W <br />CULVERT G-5 <br />PROGRAM INPUT DATA: <br />DESCRIPTION VALUE <br />Culvert Diameter (feet) ................................. 3.00 <br />FHWA Chart Number (1,2 or 3) ............................ 2 <br />Scale Number on Chart (Type of Culvert Entrancel........ 3 <br />Manning's Roughness Coefficient (n-value) ............... 0.0240 <br />Entrance Loss Coefficient of Culvert Opening............ 0.50 <br />Culvert Length (feet) ................................... 240.0 <br />Culvert Slope (feet per foot) ........................... 0.1000 <br />PROGRAM RESULTS: <br />Flow Tail.water Headwater (ft) Normal Critical Depth at Outlet <br />Rate Depth Inlet Outlet Depth Depth Outlet Velocity <br />(cfs) (ft) Control Control (ft) (ft) (ft) (fps) <br />-------------------------------------------------------------------- <br />40.4 2.00 3.60 -17.72 1.23 2.07 1.23 14.76 <br />-------------------------------------------------------------------- <br />-------------------------------------------------------------------- <br />PIPE CULVERT ANALYSIS COMPUTER PROGRAM Version 1.7 Copyright (01986 <br />Dodson L Associates, Inc., 7015 W. Tidwell, 1107, Houston, TX 77092 <br />(713) 895-8322. All Rights Reserved. <br />• <br />0