Laserfiche WebLink
EXHIBIT E — RECLAMATION PLAN <br />Field data recorded during sample collection included: <br />Color— dark gray <br />Texture — Very fine - grained clay and silt with larger clumps that are friable with <br />moderate pressure between fingertips <br />Plasticity— High <br />Moisture — Moist <br />The field sample was delivered to Aguirre Geotechnical Engineers of Englewood, <br />Colorado, and the following tests were performed: <br />Gradation Analysis — 1 1 /2" through No. 200 sieve <br />Atterberg Limits — ASTM D -4318 <br />Standard Proctor— ASTM D -698 <br />Modified Proctor— ASTM D -1557 <br />Data Analysis /Sample Material Suitability <br />The results of the geotechnical tests are as follows: <br />Gradation Analysis (Percent Fines) — 95.9% of material passed through a No. <br />200 sieve <br />Atterberg Limits — Plastic Limit = 15 <br />Plasticity Index = 24 <br />Liquid Limit = 39 <br />Standard Proctor— Optimum Moisture Content = 16.2% <br />Laboratory Maximum Dry Density = 108.9 pcf <br />Modified Proctor— Optimum Moisture Content = 13.9% <br />Laboratory Maximum Dry Density = 117.7 pcf <br />The overall goal in choosing a liner material is to obtain minimal hydraulic <br />conductivity. Benson et al., 1992, has shown empirical relationships with respect <br />to hydraulic conductivity between plasticity index, percent fines, and clay content. <br />The ranges of hydraulic conductivities for the above three factors are shown in <br />Table 1. <br />Challenger Pit <br />M-1980-026 TR -04 <br />5 Page2of6 <br />