Laserfiche WebLink
Phase 5 HVSC Pipe Diversion Flow Capacity Calculations <br />(Utilized methodology from Amendment #9, Volume V, Appendix C.8) <br />Pipe 1— Flow Capacity Required <br />• 4.08 ac. Watershed area <br />• 0.003 gpm /ft solution application rate <br />4.08 ac x 43,560 ft /ac = 177,725 ft <br />177,725 ft 0.003 gpm /ft = 533.2 gpm <br />Pipe 2 — Flow Capacity Required <br />• 8.46 ac. Watershed area <br />• 0.003 gpm /ft Approximate solution application rate <br />8.46 ac x 43,560 ft /ac = 368,518 ft <br />368,518 ft 0.003 gpm /ft = 1,105.6 gpm <br />Attachment 2 <br />Pipes 1 & 2 — Flow Capacity Assumptions <br />• Considered Secondary Pipe - 15" Dia. ADS N -12, Manning's n = 0.012 <br />• Slope ft/ft = 0.03 <br />Flow Capacity Calculations: <br />Utilizing the Flow Equation: <br />Q = (1.49 /n)AR /3 <br />Pipe 1— Flow Capacity <br />@ 15" Diameter <br />Q = (1.49 /0.012)(1.23)(0.31 /3 )(0.03 1/2 ) A = 1.23 ft <br />= 12.1 cfs R = 0.31 ft <br />12.1 cfs x 448.83 gpm /cfs = 5,430.8 gpm > 533.2 gpm — OK <br />Pipe 2 — Flow Capacity <br />@ 15" Diameter <br />Where: Q = gpm <br />N = Manning's Coefficient <br />A = Flow Area <br />R = Hydraulic Radius <br />S = Pipe Slope <br />Q = (1.49 /0.012)(1.23)(0.31 /3 )(0.03 1/2 ) A = 1.23 ft <br />= 12.1 cfs R = 0.31 ft <br />12.1 cfs x 448.83 gpm /cfs = 5,430.8 gpm > 1,105.6 gpm — OK <br />