Laserfiche WebLink
I 1 <br />~J <br />Structure #1 (Silt Fence) <br />Silt Fence Inputs: <br />Structure Detai/; <br />Fence Flow Width along Land Slope Te-back <br />Rate contour (R) Height (ft) (%) distance (ft) <br />(gpm/sq ft) <br />10.0 100.0 2.5 66.00 3.8 <br />*Sediment Storage: 0.00 ac-R <br />Silt Fence Results: <br />*No sediment capacity defined <br />Peak Fence Stage: 0.05 ft <br />Peak water Sage: 0.05 ft <br />Dewater Time: 0.02 days <br />T2p Efficiency: 59.81 <br />Dewatering time is calculated from peak stage to lowest spit/way <br />• <br />• <br />SEDCAD 4 for Windows <br />Copyright 1998 Pamela J. Srtnvab <br />Civil SoRware Design <br />Stage-Capacity-Discharge Table <br />Fence Stage <br /> <br />(ft) Water Stage <br /> <br />(R) Area <br /> <br />(ac) Capacity <br /> <br />(ac-ft) Discharge <br /> <br />(cfs) Dewater <br />Time <br />(hrs) <br />0.00 0.00 0.000 0.000 0.000 Top of Sediment <br />0.10 0.10 0.000 0.000 0.223 <br />0.20 0.20 0.001 0.000 ~ 0.447 <br />0.30 0.30 0.001 0.000 0.671 <br />0.40 0.40 0.001 0.000 0.897 <br />0.50 0.50 O.Q02 0.000 I.123 <br />0.60 0.60 0.002 0.001 1.349 <br />0.70 0.70 0.002 0.001 1.576 <br />0.80 0.80 0.003 0.001 1.804 <br />0.90 0.90 0.003 0.001 2.033 <br />1.00 1.00 0.003 0.002 2.262 <br />I.IO 1.10 0.004 0.002 2.492 <br />1.20 1.20 0.004 0.002 2.722 <br />1.30 1.30 0.005 0.003 2.954 <br />1.40 1.a0 0.005 0.003 3.186 <br />1.50 1.50 0.005 O.OC4 3.418 <br />1.fi0 1.60 O.OC6 0.004 3.651 <br />1.70 1.70 O.CCfi 0.005 3.885 <br />1.80 1.80 0.006 0.006 4.120 <br />6 <br />Filename: GVB6-t.sca <br />TR•17 <br />Exh-8 - 121 - <br />Panted Oa•18-2000 <br />6'00 <br />