My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2013-01-24_HYDROLOGY - M1977348
DRMS
>
Day Forward
>
Hydrology
>
Minerals
>
M1977348
>
2013-01-24_HYDROLOGY - M1977348
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:12:20 PM
Creation date
1/25/2013 12:45:15 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
M1977348
IBM Index Class Name
HYDROLOGY
Doc Date
1/24/2013
Doc Name
Fourth Quarter 2012 Groundwater Sampling
From
Golder Associates
To
DRMS
Permit Index Doc Type
Hydrology Report
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
39
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
ACZ Laboratories, Inc. <br />2773 Downhill Dnve Steamboat Spnngs, CO 80487 (800) 334 -5493 <br />Batch A distinct set of samples analyzed at a specific time <br />Error( + / -) Calculated sample specific uncertainty <br />Found Value of the QC Type of interest <br />Limit Upper limit for RPD, in <br />LCL Lower Control Limit, in % (except for LCSS, mg /Kg) <br />LLD Calculated sample specific Lower Limit of Detection <br />PCN /SCN A number assigned to reagents /standards to trace to the manufacturer's certificate of analysis <br />PQL Practical Quantitation Limit <br />QC True Value of the Control Sample or the amount added to the Spike <br />Rec Amount of the true value or spike added recovered, in % (except for LCSS, mg /Kg) <br />RER Relative Error Ratio, calculation used for Dup. QC taking into account the error factor <br />RPD Relative Percent Difference, calculation used for Duplicate QC Types <br />UCL Upper Control Limit, in % (except for LCSS, mg /Kg) <br />Sample Value of the Sample of interest <br />DUP <br />LCSS <br />LCSW <br />Sample Duplicate <br />Laboratory Control Sample - Soil <br />Laboratory Control Sample - Water <br />MS /MSD <br />PBS <br />PBW <br />Radiochemistry <br />Reference <br />Report Header Explanations <br />QC Sample Types <br />Matrix Spike /Matrix Spike Duplicate <br />Prep Blank - Soil <br />Prep Blank - Water <br />QC Sample Type Explanations <br />Blanks <br />Control Samples <br />Duplicates <br />Matrix Spikes <br />H Analysis exceeded method hold time <br />M <br />SM <br />D <br />RP <br />ESM <br />(1) <br />(2) <br />(3) <br />(4) <br />REP003 09.12.01 <br />Verifies that there is no or minimal contamination in the prep method procedure <br />Verifies the accuracy of the method, including the prep procedure <br />Verifies the precision of the instrument and /or method <br />Determines sample matrix interferences, if any <br />ACZ Qualifiers (Qual) <br />Method Prefix Reference <br />EPA methodology, including those under SDWA, CWA, and RCRA <br />Standard Methods for the Examination of Water and Wastewater <br />ASTM <br />DOE <br />DOE /ESM <br />Comments <br />Solid matrices are reported on a dry weight basis <br />Preparation method "Method" indicates preparation defined in analytical method <br />QC results calculated from raw data Results may vary slightly if the rounded values are used in the calculations <br />An asterisk in the "XQ" column indicates there is an extended qualifier and /or certification <br />qualifier associated with the result <br />For a complete list of ACZ's Extended Qualifiers, please click http. / /www.acz.com /public /extquallist.pdf <br />Page 29 of 34 <br />
The URL can be used to link to this page
Your browser does not support the video tag.