Laserfiche WebLink
SEEP WATER <br />COLLECTION <br />CHANNEL <br />DETAIL - BOLLARD <br />(TYP. OF 2) <br />4 "0 IRON PIPE <br />CONCRETE FILLED <br />PAINTED RED <br />ill <br />CO NCRETE <br />ENCA SEMENT <br />PLAN - FLUME <br />NOT TO SCALE <br />AIR SUPPLY PIPING <br />..•- - FROM COMPRESSOR <br />O � <br />z <br />me <br />rn <br />DETAIL - FLUME <br />INTAKE <br />STRUCTURE <br />DETAIL - FLUME <br />SCALE: 1' = 10' <br />I I <br />I I <br />I I <br />I I <br />x J <br />PUMP STATION <br />DISCHARGE LINE <br />(APPROXIMATE <br />LOCATION SHOWN) <br />EXISTING <br />c PUMP STATION <br />PRECAST CONCRETE <br />VAULT <br />NOTE: PLACE 4" x 2' <br />FOAM BOARD INSULATION <br />ABOVE PIPE. <br />k 0 <br />3" HDPE FROM <br />EXTRACTION WELLS <br />3' -0" <br />A MIN 7' BURY DEPTH <br />UNDER ROADWAY 3" HOPE FROM <br />EXTRACTION WELLS <br />< < <br />1 A 45' BENDS 4 1 <br />(TYP OF 2) �1 <br />ADD 6" THICK GRAVEL <br />?. <br />PAD FOR LEVELING <br />CONCRETE CHANNEL <br />2' -0" <br />L <br />< <br />< , <br />SECTION - FLUME <br />SCALE: 1" = 1' <br />1< .• <br />L l L <br />4' 0" <br />FILL AREA WITH CONCRETE <br />TO MATCH TOP OF FLUME <br />ELEVATION <br />2'x4' SLAB TYPE HINGED FRAME & COVER <br />J —MARK J- 1881 —D OR EQUAL <br />CONTRACTOR TO VERIFY <br />FRAME INSET REQUIREMENTS <br />PRIOR TO CASTING VAULT <br />PARSHALL FLUME <br />SCALE: 1" = 1' <br />{< L <br />PLAN - FLUME <br />RECORD <br />DRAWING <br />STAFF GAUGE <br />1' -6" ± <br />PARSHALL FLUME WITH 1" THROAT WIDTH <br />FLUME LINER BY PLASTI —FAB OR APPROVED EQUAL <br />1'1 < <br />< <br />2' 0" <br />6" PVC DISCHARGE <br />TO SEEP WATER <br />INTAKE STRUCTURE <br />CORE DRILL HOLE <br />FOR DISCHARGE PIPE <br />(GROUT SEAL PIPE IN— PLACE) <br />/ I <br />L C F < <br />6" PVC DISCHARGE <br />TO SEEP WATER <br />INTAKE STRUCTURE <br />TOP OF WALL <br />SEEP WATER INTAKE <br />STRUCTURE <br />2' -0" <br />REV <br />RECORD DRAWING <br />ISSUED FOR CONSTRUCTION <br />DESORPTION OF REVISION <br />WHH <br />RCF <br />sr <br />11/12/10 <br />10/10/01 <br />DATE <br />HENDERSON MILL <br />PHASE 1 EXTRACTION WELL SYSTEM <br />URS <br />URS CENTER <br />8181 East Tufts Ave. <br />Denver, CO 80237 -2837 <br />(303) 694 -2770 <br />WARNING <br />0 0 1 <br />IF THIS BAR DOES <br />NOT MEASURE 1 <br />THEN DRAWING IS <br />NOT TO SCALE <br />DEONNED: RCF <br />DRAWN: SAS <br />CHECKED, <br />PER REVIEWER <br />RROJFCT WAVER: <br />DAT 7 -24 -01 <br />DETAIL - FLOW METER <br />REVISION <br />RROJECi 6800044594.01 <br />DRAWN <br />3 <br />SHEET 3 OF 4 <br />