Laserfiche WebLink
ENERGY <br />Analyte <br />IV <br />QA /QC Summary Report <br />Prepared by Casper, WY Branch <br />Client: Cotter Corporation Report Date: 10/23/12 <br />Project: Schwartz SW 10/4/12 S26647 Work Order: C12100417 <br />Method: E200.8 Analytical Run: ICPMS4- C_121019A <br />Sample ID: ICV Initial Calibration Verification Standard 10/19/12 12:28 <br />Uranium 0.0498 mg /L 0.00030 100 90 110 <br />Method: E200.8 Batch: R166109 <br />Sample ID: LRB Method Blank Run: ICPMS4- C_121019A 10/19/12 14:47 <br />Uranium ND mg /L 0 00020 <br />Sample ID: LFB Laboratory Fortified Blank Run: ICPMS4- C_121019A 10/19/12 14:52 <br />Uranium 0.0533 mg /L 0 00030 107 85 115 <br />Sample ID: 012100498- 001BMS4 Sample Matrix Spike Run: ICPMS4- C_121019A 10/19/12 18:42 <br />Uranium 0.385 mg /L 0.00030 70 130 A <br />Sample ID: C12100498- 001BMSD Sample Matrix Spike Duplicate Run. ICPMS4- C_121019A 10/19/12 18:46 <br />Uranium 0.376 mg /L 0.00030 70 130 2.2 20 A <br />Qualifiers: <br />RL - Analyte reporting limit. A - The analyte level was greater than four times the spike level. In <br />accordance with the method % recovery is not calculated. <br />ND - Not detected at the reporting limit. <br />www.energylab.com <br />Astj al Excellence Stu 1052 <br />Helena, NT 877 -472 -0711 • Billings, MIT 800- 735 -4489 • Casper, WY 888- 235 -0515 <br />Gillette, WY 866 - 686 -7175 • Rapid City, SD 888- 672 -1225 • College Station, TX 888 - 690 -2218 <br />Count Result Units RL %REC Low Limit High Limit RPD RPDLimit Qual <br />Page 3 of 7 <br />