Laserfiche WebLink
Table 5: <br />Well Specifications. <br />8 <br />Casing Depths (ft TVD) <br />Hole Size <br />Casing Description <br />Cement Design <br />Cement Installation <br />Method <br />Horizontal Heater <br />Conductor <br />60 -200 ft <br />17-1/2 <br />13 -3/8 in, 48.0 lbs /ft, H -40 <br />Grade steel, STC, ID: 12.715 <br />Premium Plus <br />cement, 11.5 ppg, <br />additives as required <br />by lab test. <br />Cement annulus via <br />tremmie pipe or through <br />stab -in cementation. <br />Isolation <br />(Contingency) <br />1,100 ft — <br />1,200 ft <br />17 -1/2 in <br />13 -3/8 in, 48.0 lbs /ft, H -40 <br />Grade steel, STC, ID: 12.715 in <br />( *) <br />Premium Plus 9,5 to <br />11.5ppg Lead, 13.5 <br />to 15.8 ppg Tail). <br />Additives as required <br />by lab test. <br />Mud flush, water flush, <br />cement & displace by one <br />plug system is used to <br />pump cement job. Pump <br />cement to surface. <br />Intermediate <br />2,200 ft — <br />2,600 ft <br />12-1/4 in <br />9 -5/8 ", 40 lbs /ft , J -55, STC, ID: <br />8.835 in ( *) <br />Premium Plus <br />cement, 9.5 to 11.5 <br />ppg lead, and a 13.5 <br />to 15.8 ppg tail, <br />additives as required <br />Mud flush, water flush, <br />cement & displace by one <br />plug system is used to <br />pump cement job. Pump <br />cement to surface. <br />by lab test. <br />Heater <br />Canister <br />Well TD <br />8 -1/2 in <br />4 -1/2 ", HS -70, ASTM A -606, <br />Type 4, 0.25 WT Coiled Tubing <br />canister containing heater and <br />instrumentation <br />N/A <br />N/A <br />Inclined Producer <br />Surface <br />60 -200 ft <br />17 -1/2 in <br />13 -3/8 in, 48.0 lbs/ft, H -40 <br />Grade steel, STC, ID: 12.715 in <br />Premium Plus <br />cement, 11.5 ppg, <br />additives as required <br />Cement annulus via <br />tremmie pipe or through <br />stab -in cementation. <br />by lab test <br />Intermediate <br />2,000 ft- <br />2,200 ft <br />12 -1/4 in <br />9 -5/8 ", 40 lbs /ft , J -55, STC or <br />equivalent, ID: 8.835 in ( *) <br />Premium Plus <br />cement, 9.5 to 11.5 <br />ppg lead, and a 13.5 <br />to 15.8 ppg tail, <br />additives as required <br />by lab test. <br />Mud flush, water flush, <br />cement & displace by one <br />plug system is used to <br />pump cement job. Pump <br />cement to surface. <br />Production <br />Well TD <br />8 -1/2 in <br />6 -5/8" Slotted Liner <br />N/A <br />N/A <br />( *) Note: Higher grade may be required based on corrosion study. <br />Table 5: <br />Well Specifications. <br />8 <br />