Laserfiche WebLink
PROGRAM OUTPUT LISTS ALL THE INPUT PARAMETERS AND THE <br /> CALCULATED PARAMETERS , WHICH ARE : <br /> 10-YEAR PEAK RAINFALL INTENSITY TO SATURATE , <br /> RUNOFF IN INCHES , 10-YR-24-HR, <br /> RUNOFF IN ACRE-FEET , 10-YR-24-HR , <br /> PEAK FLOW IN CUBIC FEET PER SECOND. <br /> THESE PRINT-OUTS HAVE THE HEADING "RUNOFF" FOR EACH DRAINAGE <br /> BASIN. FOR OPEN CHANNEL FLOW CALCULATIONS , THE PROGRAM <br /> CALLS FOR THE FOLLOWING PARAMETERS : <br /> CHANNEL SHAPE , TRAPEZOIDAL , PARABOLIC , & CIRCULAR , <br /> DIMENSIONS, DEPTH, TOP, AND BOTTOM, OR, DIAMETER, <br /> SLOPE , FEET DROP PER FOOT RUN, <br /> LENGTH, FEET, <br /> MANNINGS NUMBER , ROUGHNESS COEFFICIENT. <br /> THE PROGRAM THEN CALCULATES THE MAXIMUM FULL FLOW <br /> CHARACTERISTICS OF THE CHANNEL . THIS MAXIMUM FLOW IS NOT <br /> THE DESIGN FLOW. THE DESIGN FLOW IS THE TOTAL RUNOFF THAT <br /> WILL INFLUENCE THE CHANNEL AS CALCULATED PREVIOUSLY. THE <br /> PROGRAM THEN PRINTS THE INPUT PARAMETERS AS WELL AS THE <br /> FOLLOWING CALCULATED VALUES : <br /> WETTED PERIMETER , FEET, <br /> HYDRAULIC RADIUS, FEET, <br /> VELOEITY , FEET PER SECOND, <br /> TIME THROUGH CHANNEL , MINUTES. <br /> THE PROGRAM THEN ASKS FOR ANY NEW DESIGN PARAMETERS . THESE <br /> COULD BE : <br /> DEPTH OF FLOW, FEET , <br /> VELOCITY OF FLOW, FEET PER SECOND, <br /> FLOW, CUBIC FEET PER SECOND , <br /> MANNINGS NUMBER , ROUGHNESS COEFFICIENT . <br /> 31 <br />