My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-11-05_HYDROLOGY - C1982057
DRMS
>
Day Forward
>
Hydrology
>
Coal
>
C1982057
>
2012-11-05_HYDROLOGY - C1982057
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:10:18 PM
Creation date
11/14/2012 1:35:20 PM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1982057
IBM Index Class Name
HYDROLOGY
Doc Date
11/5/2012
Doc Name
3rd Quarter 2012 Stockpond Inspections
From
Seneca Coal Company
To
DRMS
Permit Index Doc Type
Sediment Pond Inspections
Email Name
JLE
SB1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
12
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSPECTOR'S NAME: Dennis Jones <br />FACILITY CONFIGURATION: Stockpond <br />SITE NAME: T -24 <br />MINE NAME: Seneca II -W <br />MINE I.D. NO.: C -82 -057 <br />Comments: <br />PERIODIC INSPECTION FORM <br />Stockponds or Sumps <br />Circle or write in appropriate response <br />DATE: Ct — L J <br />DATE LAST INSPECTION: 1 S "17 -0- <br />LOCATION: SW'%NEl %, Sec 9, T5N, R88W <br />LOCATION: 8 mi S of Hayden, CO <br />OWNER'S REP.: Dennis Jones, Manager <br />1. Angle of slope: 3.9:1 upstream, 4.6:1 downstream Total = 8.5:1 N/A <br />2. *Seepage (specify location, color, and approximate volume) <br />At isolated points on embankment slopes: Yes No N/A <br />At natural hillside: Yes No N/A <br />Over widespread areas: Yes No N/A <br />From downstream foundation area: Yes No N/A <br />"Boils" beneath stream or ponded water: Yes No N/A <br />3. Cracks or scarps on crest: Yes No N/A <br />4. Cracks or scarps on slope: Yes No N/A <br />5. Sloughing or bulging on slope: Yes No N/A <br />6. *Major erosion problems: Yes No N/A <br />7. Surface movements in valley bottom or on hillside: Yes No N/A <br />8. *Erosion of toe: Yes No N/A <br />9. *Water impounded against downstream toe: Yes 1� N/A <br />10. Existing embankment freeboard: R V feet <br />11. Increase Decrease in water level: R 1 feet <br />12. Cracks, bulging, or erosion on upstream face: Yes N/A <br />13. Spillway erosion: Yes 1 No l N/A <br />14. *Clogging <br />Spillway channels: Yes INo / N/A <br />Diversion ditches: Yes N N/A <br />*Major adverse changes in these items could cause instability and should be reported to <br />the Engineering Manager and Mine Superintendent for further evaluation. Adverse <br />conditions noted in these items should normally be described (extent, location, volume, <br />etc.) in the space on the back of this sheet. <br />