My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
2012-10-18_REVISION - C1980004
DRMS
>
Day Forward
>
Revision
>
Coal
>
C1980004
>
2012-10-18_REVISION - C1980004
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
8/24/2016 5:09:37 PM
Creation date
10/19/2012 7:39:50 AM
Metadata
Fields
Template:
DRMS Permit Index
Permit No
C1980004
IBM Index Class Name
REVISION
Doc Date
10/18/2012
Doc Name
Adequacy Response #1
From
J.E. Stover & Associates, Inc
To
DRMS
Type & Sequence
PR2
Email Name
MPB
SB1
Media Type
D
Archive
No
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
46
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Mike Boulay <br />-35- <br />• The flow values for ditches R22 -a, R22 -b and R22 -c should be 11.4cfs, <br />38.3 cfs and 39.3 cfs respectively instead of the listed values of 17.5 cfs, <br />42.1 cfs and 43.1 cfs. Please revise these values. <br />MCM: No longer applicable, Please see approved Table 3.1 -1. <br />98. It appears that Table 4.2 -12 needs a couple of revisions: <br />October 16, 2012 <br />• In Table 4.2 -12, it appears that the values for the right side slope and the <br />left side slope for ditch D -20 have to be switched. If this is correct, please <br />revise Table 4.2 -12 accordingly. <br />• In Table 4.2 -12, it appears that the D50 value for ditch D -24b should be 9 <br />inches instead of 12 inches. If this is correct, please revise Table 4.2 -12 <br />accordingly. <br />MCM: No longer applicable, please see approved Table 4.2 -12. <br />99. It appears that there are several culverts listed in Table 4.2 -13 that do not have <br />Sedcad design runs showing their peak flow calculations. These culverts are C -1 <br />through C -4, C -8 through C -11, C -13 and C -16 through C -18. Please provide <br />these Sedcad designs or point out where in the submittal these designs are <br />located. <br />MCM: No longer applicable, please see approved Appendix M. <br />100. It appears that several revisions need to be made to Figure 2.2 -3: <br />• It does not appear that ditch D -10 is depicted on Figure 2.2 -3, although <br />the label for this ditch is shown. If this is correct, please revise accordingly. <br />• It does not appear that ditch D -27 is shown on Figure 2.2 -3. Please revise <br />this figure if this is correct. <br />• It does not appear that ditch D -36 is labeled on Figure 2.2 -3. If this is <br />correct, please revise Figure 2.2 -3 accordingly. Shown, east of Sed Pond, <br />toe of slope <br />• The Division requests that a larger plan view of the sediment pond be <br />provided. The plan view of the sediment pond provided in Figure 2.2 -3 is <br />too small to see details. <br />• The Division requests that Figure 2.2 -3 be revised so that more of the <br />subwatershed drainage basins are shown. New Figure 2.2 -3a shows <br />