Laserfiche WebLink
Mineral Joe Mine Environmental Protection Plan 8 <br />Table 3. Samples Collected and Composited for Geochemical Testing <br />Northing_y <br />584,750 <br />584,830 <br />584,910 <br />Composite ID Samples <br />MJ WRP1 <br />MJ WRP MJ WRP2 <br />MJ WRP3 <br />Notes: WRP = representative underground mine waste rock composite <br />Sample coordinates given in State Plane Colorado South NAD 27 ft <br />The individual samples were crushed to -3/4 inch using a jaw crusher in Whetstone's geochemistry <br />facilities in Gunnison, Colorado. The samples were subsequently split using a Versa Splitter (riffle -type <br />splitter) followed by a cone and quartering method and then composited to develop the representative <br />composite samples shown in Table 4. <br />Cone - and - quarter compositing and splitting were performed by gathering the sample into a pile (cone), <br />digging out the center of the cone and distributing the material around the edges of the pile in a ring, and <br />gathering the ring back into a center cone. The procedure homogenizes the sample and was repeated three <br />times. The cone was then split into equal quarters, and opposite quarters were combined to produce a <br />representative split. Sequential generations of splits were combined until the sample for the composite was <br />within the target weight. <br />The samples were then crushed further to approximately minus 10 Mesh in an impact mill and split using <br />the cone and quartering method to obtain the weights shown in Table 4. <br />The final splits were sent to Energy Laboratories for analysis, with a request to process and analyze them in <br />their entirety. These procedures were implemented to avoid potential sample bias related to shipping, <br />settlement, and unrepresentative splitting at the analytical lab. The resulting composited samples are <br />believed to be representative of the materials of interest. <br />Table 4. Mass of Composited Samples Submitted for SPLP, Whole Rock, and ABA <br />Analysis <br />Composite ID <br />MJ WRP <br />Sample ID <br />MJ WRP SPLP <br />MJ WRP WR <br />MJ WRP ABA <br />Notes: WRP = representative underground waste pile composite <br />SPLP = sample designated for synthetic precipitation leaching procedure <br />WR = sample designated for whole rock analysis <br />ABA = sample designated for acid base accounting analysis <br />Easting x <br />1,073,240 <br />1,073,195 <br />1,073,160 <br />Weight (g) <br />204.6 <br />114.5 <br />106.4 <br />5.3.3.2 Acid Base Accounting Results <br />Acid -base accounting (ABA) tests were used to evaluate the potential for ore and waste rock material to <br />generate acid rock drainage. Acid -base accounting provides a theoretical estimate of the net acid - <br />producing potential of rock materials by comparing the total acid generating potential (AGP) to total acid <br />neutralizing potential (ANP). Test results are generally evaluated by calculating the net neutralizing <br />potential (NNP = ANP -AGP) or by the ratio of ANP to AGP (ANP /AGP). Samples with NNPs greater <br />than 20 and ANP /AGP ratios greater than 3 are considered to have low potential to produce acid. Samples <br />4148B.120927 Whetstone Associates <br />